Baldwin Boxall Communications Ltd.

Wealden Industrial Estate, Farningham Road
Crowborough, East Sussex, TN6 2JR
Telephone: 01892 664422    Fax: 01892 663146
Website: www.baldwinboxall.co.uk
Email: [email protected]

C   O   M   M   U   N   I  C   A   T   I  O   N   S

IBVE

Issue 6   14/07/2004

ECR 1597

VIGIL ECLIPSE

(Compact Software Version COMP4)

Integrated Voice Alarm System

Installation and Operating

Instructions

Summary of Contents for VIGIL ECLIPSE

Page 1: ...Sussex TN6 2JR Telephone 01892 664422 Fax 01892 663146 Website www baldwinboxall co uk Email mail baldwinboxall co uk C O M M U N I C A T I O N S IBVE Issue 6 14 07 2004 ECR 1597 VIGIL ECLIPSE Compact...

Page 2: ...achment 1 BVCOM Instruction Manual Attachment 2 BVSMP Instruction Manual Attachment 3 BV440M Instruction Manual Attachment 4 BV220 Instruction Manual Attachment 5 Attachment 6 BV120D Instruction Manua...

Page 3: ...ered by a 230V AC 50 60Hz power supply with internal battery backup The VIGIL Eclipse is supplied with the necessary number of BEL1 end of line monitoring devices to provide full monitoring Front Pane...

Page 4: ...sure that the wall is strong enough to support the unit which when assembled can weigh up to approximately 75KG without batteries Diagram Showing Hole Centres For Mounting Bracket FIG 2 There are a nu...

Page 5: ...are used the Earth Return from each BEL1 must be connected to the relevant 0V connection on the Termination Board Power Up Remove battery fuses from fuse box and then install batteries into Eclipse C...

Page 6: ...6 Issue 6 INSTALLATION INSTRUCTIONS Continued Switch Any Unused Fire Mic Select Lines To ON FIG 3 Switch To ON For Continuous Surveillance Switch Any Unused Line Fault Inputs To ON FIG 4 Fig 5...

Page 7: ...k2 to call zone 3 P2 pin 6 16 FM 2 Zone 2 select Close to 0V via 1k2 to call zone 2 P2 pin 5 17 FM 2 Zone 1 select Close to 0V via 1k2 to call zone 1 P2 pin 4 18 FM 2 Ground 0V P2 pin 3 19 FM 2 Audio...

Page 8: ...stors Reverse polarity P8 pin 3 56 F P Evac zone 2 for alarm condition shown for the active P8 pin 4 57 F P Evac zone 3 i e alarm condition P8 pin 5 58 F P Evac zone 3 P8 pin 6 59 F P Evac zone 4 See...

Page 9: ...AMP6 O P 100V line loudspeaker output 6 AMP6 0V Earth for BEL1 AMP6 O P 100V line loudspeaker output 6 AMP7 O P 100V line loudspeaker output 7 AMP7 0V Earth for BEL1 AMP7 O P 100V line loudspeaker out...

Page 10: ...UN FM SEL SURV SINC EVAC Z1 EVAC EVAC EVAC Z2 Z3 Z4 RSET RSET ALT ALT AUX O P NC W NO BEL1 LINE LINE GND CCT A CCT B CCT A CCT B CCT A CCT B CCT A CCT B ZONE2 ZONE3 ZONE4 S4 S3 S2 S1 0V I P I P 39 40...

Reviews: