Care2
Installation Instructions
54
Care2 issue 7
Figure 4.28 — EOL Impedance value selected
5. Scroll up until the value shown matches that indicated in
Table 4.1 for the number of handsets stored in the Enclosure.
Table 4.1 — End Of Line Values for Handset Enclosure
6. When the EOL Value is correct for the number of handsets
in use press the encoder.
7. Scroll down to “Save and Exit”.
8. Press the encoder to save the changes and exit the Line 2
Menu.
Number of Handsets
Stored in Enclosure
Required EOL OC Value
1
< 400uA
2
< 1300uA
3
< 2150uA
4
< 3050uA
5
< 3900uA
6
< 4800uA