CONTROL PANEL
For R30
A = NEMA 515R GFCI DUPLEX. This receptacle is a ground fault circuit
interrupter duplex rated at 125 VAC, 20 amps. This receptacle must be
tested on a regular basis (monthly).
B = STANDARD DUPLEX RECEPTACLE. This is your standard household
duplex receptacle, it is rated for 120 VAC, 15 Amps. When using this
receptacle you are utilizing the ground fault protection provided by the
GFCI receptacle.
C = ELAPSED TIME METER. This meter displays a continuous running
total of the hours accumulated on the unit.
D = CIRCUIT BREAKER. This circuit breaker provides overload protection
for the generator set. When tripped, the circuit breaker plunger will extend
out approximately 3/8".
E = THE AUTO IDLER FEATURE ON/OFF SWITCH. The Auto Idler Feature allows
the engine on the generator set to slow down to a "Slow Speed Position"
when there is no load being applied to the unit. When a load is applied to the
unit, the Auto Idler Circuitry allows the engine to speed up and operate at the
Engine Governor's preset speed. When this switch is turned off, the engine will
continuously run at the preset speed of the Engine Governor.