background image

  1

Instruction Manual For D

Series Replacement Rectifier Package

SAFETY NOTICE

: WARNING statements

 describe conditions that may lead to personnel

injury including potentially fatal injuries if the machine is improperly used and

warnings are not followed.

Caution statements describe conditions that may lead to equipment

damage.

WARNING:

Be sure to read and follow all Instruction, Warning and Caution

statements in the appropriate motor manual.  Failure to do so may

result in serious or fatal injury.

WARNING:

Only qualified personnel should attempt the installation, operation

and maintenance of this equipment. Proper guards and other suitable

safety devices or procedures as may be desirable or as may be

specified in safety codes, are neither provided by Baldor nor are the

responsibility of Baldor. Safety devices are the owners responsibility.

WARNING:

Disconnect all electrical power from the motor and accessory

devices and TAG Power Source before performing this procedure.

Electrical shock can cause serious or fatal injury.

Receiving & Inspection

When you receive your control, there are several things you should do

immediately.
1. Observe the condition of the shipping container and report any damage

immediately to the commercial carrier that delivered your control.

2. Remove the control from the shipping container and remove all packing

materials from the control.  The container and packing materials may be

retained for future shipment.

3. Verify that the part number of the control you received is the same as the part

number listed on your purchase order.

4. Inspect the control for external physical damage that may have been

sustained during shipment and report any damage immediately to the

commercial carrier that delivered your control.

Description

 

This rectifier package is made for the D

Series Motor Brake. It provides either full

wave rectification (low voltage) or one

half wave rectification (high voltage) of AC

voltage input. The standard D

Series VAC Motor Brake has a rectifier located on the

brake coil internal to the brake. If the brake initially had the incorrect coil or was wired

incorrectly, this internal rectifier could be blown. The resistance of the brake coil must

be measured between brake leads B4 and B5 to ensure that the brake coil is the

correct coil and still intact. The proper resistance values are shown in Table 1. Only

if the coil resistance is verified to be correct should this replacement rectifier package

be used. This package is capable of operating at any of the standard D

Series Brake

nameplate voltages 104 through 575 VAC, 50 or 60 Hz.

Mounting

The Replacement Rectifier Package may be placed inside the motor conduit box. 

The Replacement Rectifier Package dimensions are shown in Figure 1.

Figure 1  

0.625

2.140

1.140

Wire leads are 6" long