Troubleshooting Guide

  

Trouble 

Probable Cause 

Corrective Action

  

Pump does not operate 

Inadequate air supply pressure or 

Increase or clear air supply 

(1)

 

 

 

restricted air line                                              Assure air is on and valves are open

 

 

Clogged  lines, hoses, valves, etc. 

Open; clear 

(1)

 

 

Damaged air motor 

Service / replace air motor

 

 

 

  

Air motor is not tripping over 

Air motor seals are worn/damaged 

Service / replace air motor

  

Air is leaking from exhaust 

Air motor seals are worn/damaged 

Service / replace air motor

 

and or seal damage, etc.

  

Fluid is leaking from the exhaust 

Fluid seal (8) is worn/damaged 

Replace

  

Erratic pump operation 

Air entering suction line 

Check for loose connections

 

 

Fluid level too low 

Refill, reprime or flush

 

 

Air motor icing 

Run pump at lower pressure; run at lower 

 

 

 

cycles per minute; clean muffler (38)

  

Pump runs continuously 

Empty fluid supply 

Refill, reprime or flush

 

 

Blockage in pump tube or foot valve (16) 

Remove pump tube, clear blockage

 

 

Lower ball (14) is stuck in foot valve (16) 

Replace ball and reseat foot valve

 

 

Lower seal (21) is worn or damaged 

Replace

  

Fluid output on one stroke only or 

Upper ball (19) is stuck in fluid piston (20) 

Replace ball and reseat

  

continues to operate when  

or one or both are damaged 

  

dispensing valve is closed 

 

 

Pump operates, but pump output 

Inadequate air supply pressure or 

Increase air supply; increase air supply size

  

 on both strokes is low 

restricted air line

 

 

 

 

Closed or clogged solenoid valve, meter, 

Clear

(1)

 

 

dispensing valve, etc.

 

 

 

 

Air inlet strainer/filter clogged 

Clear

(1)

  (1)  Follow  the 

Pressure  Relief  Procedure

 

and  disconnect  the  fluid  line.    If  the  pump  starts  when  the  air  is  turned  on  again, 

   the line, etc. is clogged.

NOTE:

  Check  all  other  possible 

causes before disassembling pump.

!

Summary of Contents for PANTHER 1130-011

Page 1: ...nd this manual before installing operating or servicing this equipment OPERATION INSTALLATION MAINTENANCE AND REPAIR GUIDE SERVICE BULLETIN SB1037 Rev J 1 11 PANTHER SERIES PUMPS 5 1 RATIO MODEL 1130...

Page 2: ...stem 1 Disconnect the air to the pump 2 Point dispensing valve away from yourself and others 3 Open dispensing valve until pressure is relieved WARNING WARNING THIS PUMP CONTAINS ALUMINUM AND ZINC PAR...

Page 3: ...nd foot valve for superior wear and corrosion resistance The pump s exterior is constructed from aircraft grade extruded aluminum for an outstanding strength to weight ratio The pump also has high qua...

Page 4: ...ump fluid entry port Attach the air nipple to the air inlet port of the Panther pump During assembly of the air supply line be sure to blow out all foreign materials before making connection to the pu...

Page 5: ...ump Operation WARNING Before beginning pump repair all internal pressure must be relieved To reduce risk of personal injury follow the Pressure Relief Procedure shown on page 2 and page 6 Pump Disasse...

Page 6: ...ef Procedure Pressure Relief Procedure To reduce the risk of serious bodily injury including fluid injection or splashing into the eyes and or onto the skin follow the procedure below before maintaini...

Page 7: ...ump at lower pressure run at lower cycles per minute clean muffler 38 Pump runs continuously Empty fluid supply Refill reprime or flush Blockage in pump tube or foot valve 16 Remove pump tube clear bl...

Page 8: ...1 0 0 5 12 826676 Seal Adapter 1 0 1 13 829457 Cylinder Pump 1 0 0 14 808691 Ball 1 0 1 15 830306 Seal Footvalve 1 0 1 16 829458 Footvalve prior to 4 2003 1 0 0 826060 Footvalve after 4 2003 1 0 0 17...

Page 9: ...9 Exploded View Panther 3 1 Ratio Pump Model 1130 010 See Page 12...

Page 10: ...89 Grounding Lug 90042Q05 1 0 0 5 12 800951 Seal Adapter 1 0 1 13 829459 Cylinder Pump 1 0 0 14 806962 Ball 1 0 1 15 829893 Seal Footvalve 1 0 1 16 829460 Footvalve 1 0 0 17 829662 Pin Stop 1 0 1 18 8...

Page 11: ...11 Exploded View Panther 5 1 Ratio Pump Model 1130 011 See Page 12...

Page 12: ...12 Air Motor Panther Series Pumps Models 1130 010 and 1130 011 23...

Page 13: ...Ring 4 4 36 829461 Retnr Detent 2 2 37 829661 Spring Detent 2 2 38 805810 Ball Detent 2 2 39 831553 O Ring 1 1 40 830793 Piston Air 1 0 41 829659 Felt Muffler 90036Q20 1 0 20 42 829999 Spool Detent 1...

Page 14: ...ir kit for 1130 010 1130 011 Panther pumps without Delrin inserts 900015 Air motor repair kit for Panther grease pumps 1150 006 1150 007 1150 008 Does not include piston 900016 Repair kit for lower as...

Page 15: ...15 Notes...

Page 16: ...Balcrank Corporation Weaverville NC 28787 800 747 5300 Fax 800 763 0840 www balcrank com Service Bulletin SB 1037 Rev J 1 11 For Warranty Information Visit www balcrank com...

Reviews: