MOUNTING ZONE KEYPAD
The Zone Keypad should be mounted upright with the antenna pointing upward, near a
120VAC electrical outlet.
The Keypad should be mounted to a structurally sound wall using the three holes in the
Keypad back plate. Mounting height should be 5 to 6 feet for consistent access.
Care should be taken to avoid mounting the keypad behind any steel objects that may
block
the RF signals from Hoses/Meters.
Care should be taken to avoid direct, significant, heat sources.
NOTE:
Zone Keypad should
not
be mounted within 20 feet of a Dispense Keypad.
Specifications
Power Requirements: 120VAC 50/60Hz
RF Communications: 2-way, 902-928MHz Frequency Hopping Spread Spectrum per FCC
Operating Temperature: 14° F to +140° F (-10° C to +60° C)
FCC ID: GIF-RF KEYPAD
FCC CERTIFIED, PART 15, SUB-PART C
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired opera-
tion.
7
7
3
5
8
3
8
13
16
7
7
3
5
8
3
8
13
16
MOUNTING DIMENSIONS FOR KEYPAD
(HOLES ON KEYPAD ARE THREADED FOR A M6 x 1 SCREW)
5
Keypad Mounting Dimensions
(Holes on Keypad are threaded for a M6X1 screw)