Balboa ML260 User Manual Download Page 10

Page 8

Jets 2

(optional on some systems)

Press the “Jets 2” button once to turn pump 2 on or 
off, and to shift between low and high speeds if it is 
a two-speed pump. If left running, the pump will turn 
off after a timeout period.

Jets 3, Jets 4

(optional on some systems)

Press the “Jets 3” button once to turn pump 3 on or 
off, and to shift between low and high speeds if it is a 
two-speed pump. If left running, the pump will turn off 
after a timeout period. “Jets 4” operates the same way 
as “Jets 3”.

Jets 5, Jets 6

(optional on some systems)

Press the “Jets 5” button once to turn pump 5 on or off. 
If left running, the pump will turn off after a timeout 
period. “Jets 6” operates the same way as “Jets 5”.

Mister 

(optional)

Press the “Mister” button to turn the Mister on and off. 
If left on, the mister will automatically turn off after 
15 minutes.

Option 

(optional)

Press the “Option” button to turn optional equipment 
(such as TV or Stereo) on and off (with no timeout).

TV Lift 

(optional)

Press the “TV Lift” button to raise and lower the TV Lift 
device. There is no timeout for this feature.

Blower 

1-speed operation: on/off;
2-speed operation: med/hi/off; or
3-speed operation: lo/med/hi/off.
If left on, the blower will automatically turn off after a 
timeout period.

Fiber 

(optional on some systems)

If a fiber-optic light with wheel is installed, press the 
“Fiber” button once to start the light and wheel, press 
it again to stop the wheel, and then again to turn the 
light off. The fiber icon stands still when the fiber-optic 
light is on by itself, and rotates when the color wheel is 
also on.

Both spa light and fiber-optic light can be used 
simultaneously on systems that have both. If either light 
is left on, it will automatically turn off after a timeout 
period (on some systems this timeout can be as long as 
4 hours.)

Use the “Light” button if your fiber-optic system is on/off
only (no separate wheel stop).

Stir  

(optional on some systems)

Press the “Stir” button after adding new chemicals into 
the spa. This will turn all pumps on at high-speed for 
5 minutes to thoroughly mix in the chemicals.

Optional Auxiliary Panels

Note:

Below is a partial list of optional auxiliary panels and their basic functions.

Please contact for local dealer for a complete list of options that will work with your spa.

Blower

Jets 1

Jets 1

Jets 2

Light

Light

Blower

Jets 1

Jets 1

Jets 2

Jets 1

Jets 2

Jets 1

Jets 2

Jets 1

Jets 1

Jets 2

Jets 2

Blower

Blower

Summary of Contents for ML260

Page 1: ...Light Temp Jets Aux Light Temp Jets Note regarding EL and GL systems Mach 3 EL and GL systems function identically but conform to different International requirements This user guide will refer to EL...

Page 2: ......

Page 3: ...shutting off automatically Certain conditions filters or freeze can cause a function to operate longer while faults can cause a function to operate for a shorter length of time The system keeps track...

Page 4: ...Mode Pressing Temp followed by Aux or Jets 2 or Blower will turn off all spa functions temporarily This is helpful when changing a filter Pressing any button exits Standby mode On some systems the Jet...

Page 5: ...the temperature thresholds determined by the switch See your dealer for details Locking Features If this panel is used as the main panel locking features will not be available If this panel is used as...

Page 6: ...factory default When set to through the number is the address see your Dolphin II manual for details Editing User Preferences View the setting The left two characters before the decimal point tell you...

Page 7: ...reset the GFCI and the spa will operate normally from that point You can verify a successful test by navigating to the item as described above pressing Jets and then pressing the Temp button until you...

Page 8: ...nce the heater has cooled reset by pushing any button If spa does not reset shut off the power to the spa and call your dealer or service organization DO NOT ENTER THE WATER Remove the spa cover and a...

Page 9: ...solid on the display when the temperature is not current will alternate with the temperature when the temperature is current Operates the same as Standard mode then reverts to Economy mode after 1 hou...

Page 10: ...operation med hi off or 3 speed operation lo med hi off If left on the blower will automatically turn off after a timeout period Fiber optional on some systems If a fiber optic light with wheel is in...

Page 11: ...nnect only to a circuit protected by a Class A ground fault circuit interrupter To ensure continued protection against shock hazard use only identical replacement parts when servicing Install a suitab...

Page 12: ...o not attempt service of this control system Contact your dealer or service organization for assistance Follow all owner s manual power connection instructions Installation must be performed by a lice...