Doc P/N 40232 Rev. B

Basic Installation and Configuration Guidelines for 

Mach 2.1 EL-Series Spa Controllers.

IMPORTANT:  The System must be properly mounted. Do not rely on the plumbing 
connection to support the system. Regular operation will cause excessive vibration and 
potential damage to the system unless it is mounted securely.

Use minimum 6AWG copper conductors only.

Torque field connections between 
21 and 23 in lbs.

Readily accessible disconnecting means to be 
provided at time of installation

Permanently connected

Connect only to a circuit protected by a Class A 
Ground Fault Circuit Interrupter (GFCI) mounted at 
least 5’ (1.52M) from the inside walls of the  
tub and in line of sight from the equipment 
compartment.

CSA enclosure:  Type 2

Refer to Wiring Diagram inside the cover of the control enclosure.

Refer to Installation and Safety Instructions provided by the spa manufacturer.

Warning:

 People with infectious diseases should not use a spa or hot tub.

Warning:

 To avoid injury, exercise care when entering or exiting the spa or hot tub.

Warning:

 Do not use a spa or hot tub immediately following strenuous exercise

Warning:

 Prolonged immersion in a spa or hot tub may be injurious to your health

Caution:

 Maintain water chemistry in accordance with the Manufacturers instructions.

Caution:

 The equipment and controls shall be located not less than 1.5 meters horizontally from 

the spa or hot tub.

Typical field connections for main power.

Compatible with system software rev 100-1xx-10 or higher

Doc P/N 40232 Rev. B

04-05-2006

© Copyright 2006 Balboa Instruments, Inc.

GREEN

WHITE

WHITE AC (120 V) 

FOR W-WIRES

120V
Heater
Jumper
(remove
for 240V
Heater)

RED AC (240 V) 

FOR W-WIRES

BLACK

RED

FROM GFCI 

J23  J19  J28
J43  J42  J48 

J53  J54 
J55  J25 