![Balboa EL1500 v35 Tech Sheet Download Page 19](http://html1.mh-extra.com/html/balboa/el1500-v35/el1500-v35_tech-sheet_3551818019.webp)
Page 19
EL1500 - 40916_01_C
ML40x/ML2xx Custom Button 1
1
2 3 4 5 6 b g F E o t d P n A
U
r O H 9 L 8 7
ML40x/ML2xx Custom Button 2
1
2 3 4 5 6 b g F E o t d P n A
U
r O H 9 L 8 7
ML40x/ML2xx Custom Button 3
1
2 3 4 5 6 b g F E o t d P n A
U
r O H 9 L 8 7
1-6 =
Assigns Pump Number (Pump 1, Pump 2, etc);
b =
Blower;
g =
Spa Light;
F =
Fiber-Optic wheel/light;
E =
EitherLight;
o =
Option 1;
t =
Mister 1;
d =
Mister 2/Cool;
P =
Mister 3/Elec Heat;
n =
Ext Heat;
A =
Sound Mode Select;
U =
Button Disabled (DO NOT USE)
;
r =
Air Valve;
O =
Option 2;
H =
Option 3;
9 =
Invert;
L =
Option 4;
8 =
Stir ;
7 =
Option 5
ML400
1
2
3
ML200
3
2
1
ML260
3
2
1
ML240
3
2
1
Temp
Temp
Temp
Temp
Temp
Temp
Temp
Temp
ML40x/ML2xx Custom Buttons Enable
n
Y
n
=
Disabled;
Y
=
Enabled;
= 1 DIP Switch
Special Amperage Rule*
1
2 3 4
1
=
Blower off when 2nd high-speed pump on;
2
=
Max 1 high-speed pump
3
=
Max 2 high-speed pumps;
4
=
Max 2 high-speed pumps + Blower off when 2nd high-speed pump on
*Note: DIP A11 must be ON to use Special Amperage Rule.
DR
Mode
n
Y
n
=
Disabled;
Y
=
Enabled
Demo
Mode
n
Y
n
=
Disabled;
Y
=
Enabled
GFCI Test Enable
n
1 2 3 4 5 6 7
n
= Disabled;
1
= Auto after 1 day;
2
= Auto after 2 days;
3
= Auto after 3 days;
4
= Auto after 4 days;
5
= Auto after 5 days;
6
= Auto after 6 days;
7
= Auto after 7 days
Software Configuration Settings Continued
ML40
X
/ML2
XX
S
ERIES
B