INSTALLATION INSTRUCTIONS AND  

MAINTENANCE MANUAL 

FOR 

BALBOA ULTRAVIOLET SANITITION SYSTEMS 

 

 

 
 
 
 
 
 

MADE IN THE USA 

 

BALBOA WATER GROUP 

1382 BELL AVE - TUSTIN - CA - 92780 – USA 

www.balboawater.com 

 

Summary of Contents for 59060

Page 1: ...Rev 04 12 2016 02 INSTALLATION INSTRUCTIONS AND MAINTENANCE MANUAL FOR BALBOA ULTRAVIOLET SANITITION SYSTEMS MADE IN THE USA BALBOA WATER GROUP 1382 BELL AVE TUSTIN CA 92780 USA www balboawater com ...

Page 2: ...ical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction 5 Children being supervised not to play with the appliance 6 This unit contains a UV C lamp 7 WARNING Do not operate the UV C lamp when it is removed from the unit enclosure 8 Unintended use of the unit or damage to the housing may result in the escape of dangerous UV C ra...

Page 3: ...v 04 12 2016 02 VI Plumbing A Use 3 4 clear flexible hoses 3 4 hose clamps for both inlet and outlet connections B This unit can be plumbed with one of the bellow options a Option 1 b Option 2 c Option 3 ...

Page 4: ...lamp 20 This can cause severe eye damage or blindness f Drain water out of the unit completely g Remove enclosure cover 14 h Make sure to use latex glove when handling the UV C lamp 20 i Disconnect UV C lamp connector 17 from ballast connector 16 j Slowly remove boot cover 18 and UV C lamp 20 from quartz tube 6 k Remove quartz seal compression nut 11 l Use bare hands carefully to remove quartz sea...

Page 5: ...s a Danger Turn the spa breaker to OFF position b Open the spa controller s cover and disconnect the unit from the spa controller c Warning Allow UV C lamp 20 to cool down prior to removing from the unit d Danger Never look at the lit UV C lamp 20 This can cause severe eye damage or blindness e Remove enclosure cover 14 f Make sure to use latex glove when handling the UV C lamp 20 g Slowly disconn...