49-328P50 – 

www.hydroair.dk

 – February 2009 

Genesis Blower 

 
Note 

The standard version of the Genesis air blower is constructed for use on whirlpools, spas and similar applica-
tions for private use only. The Genesis air blower is not constructed for use together with a separate portable 
mat and must never be used as a portable unit. 
 

Dry-out functions

The blower has manual and automatic dry-out functions which are controlled by a timer. 
1. Manual 

function: 

 

When the blower has been switched off after a bath, it will remain switched off for 30 minutes and then 
a 5-minute dry-out will start. 

 
2. Automatic 

function: 

 

When the blower has been running for 30 minutes, it will be switched off automatically. The blower will 
remain switched off for 30 minutes and then a 5-minute dry-out will start. 

 
This function is only integrated in the following types of blower: 
3-speed, pneumatic switch 
3-speed, pneumatic switch with heater 
Variable speed 
Variable speed with heater 
 

Location 

The Genesis air blower must be mounted in a suitable place which does not allow accessibility without use of a 
tool and is protected from flooding. It must also be placed in a well-ventilated location, but avoid cold air intake 
as this will cause a cold air injection into the whirlpool or spa. 
 

Installation 

The blower is suitable for mounting below whirlpools and spas. It must be secured to the installation place by 
means of three screws fitted through the three rubber feet of the blower. The bottom of the blower can be op-
ened by loosening the two screws located under the blower label at the back. The blower should not be acces-
sible to people using the whirlpool or spa. Water flowing back from the whirlpool or spa must not come into con-
tact with the blower. To ensure this, we recommend that the pipe or hose system be laid so that a double air 
loop and one check valve, or two check valves, are fitted above the maximum water level. The pipe/hose system 
must be securely fixed to the blower’s outlet. If the blower is a heated version, bear in mind that the heater will 
switch off automatically if the air temperature rises above approx. 50°C (*). For pneumatically controlled air 
blowers, flexible piping with an internal diameter of 3 mm. must be fitted to the air switch which is located at the 
back of the blower. 

(*) Remark 

EN 60335-2-60 (

excerpt

): 

11.8: 

Supplement: When a heating element is built into the device, 

the water temperature of the bathing water should not exceed 

50°C

at the inlet

Warning

It is essential that the pipe or hose system always has a double air loop and 
one check valve, or two check valves, fitted above the maximum water level

.

Summary of Contents for HydroAir Genesis

Page 1: ...ause a cold air injection into the whirlpool or spa Installation The blower is suitable for mounting below whirlpools and spas It must be secured to the installation place by means of three screws fit...

Page 2: ...east 3 mm in each pole If the single speed blower is fitted to an external variable speed control box the blower must run at high speed for at least 5 seconds Note If the thermal protection for the ai...

Page 3: ...das Gebl se f r sp te re Inspektionen und Wartungsarbeiten zug nglich ist Installation Das Gebl se eignet sich f r eine Installation unter der Badewanne darf aber f r den Badenden nicht zug nglich sei...

Page 4: ...hoher Drehzahl eingeschaltet werden und mindestens f r 5 Sekunden dieser Drehzahl laufen Achtung Wenn sich der thermische Schutzschalter des Gebl semotors ausgel st hat kann das Gebl se erst wieder a...

Page 5: ...etien Installation Le blower peut tre install en dessous d une baignoire et doit tre fix l installation par le biais de trois vis qui seront ins r es dans les trois pieds en caoutchouc du blower La ba...

Page 6: ...en version standard il est important que si une com mande de variation de vitesse est utilis e le d marrage se fasse en pleine puissance V max et ce pour une dur e minimum de 5 secondes Note Veuillez...

Page 7: ...rk Bl seren skal installeres et sted som muligg r fremtidige eftersyn og vedligeholdelse Installation Bl seren er velegnet til montering under badekarret Den skal fikseres ved hj lp af 3 skruer som p...

Page 8: ...Hvis en standardbl ser er tilkoblet en ekstern variabel kontrolboks skal bl seren k re med maksimum ydelse i min 5 sekunder Bem rk Hvis termosikringen i bl seren sl r fra vil bl seren ikke kunne gens...

Reviews: