Power Requirements:
120/240VAC, 60Hz, 16/40A, Class A GFCI-protected service (Circuit Breaker = 20/50A max.),
3 or 4 wires [hot, hot (optional), neutral, ground].
Do not use this setup with a 3 kW heater.
System Ouputs:
Pump 1
120VAC
2-Speed
12A max
30-minute timer for Low Speed, 15 Minutes for High Speed
This is the heater pump and must be the same voltage as the Ozone
Must deliver a minimum of 20 GPM through heater
Ozone
120VAC
.5A max
Uses the same relay as Pump 1 Low
Must be the same voltage as heater pump
Spa Light
12VAC
On/Off
1A max
4-Hour timer.
Heater
1kW @ 120VAC or 4kW @ 240VAC
Misc.
J23 & J32
Not Applicable with 120V Heater.
Wiring Diagram and Settings
Setup 7
WS07
L2
L1
N
F3 10A 250V
F2 3A 250V
F6 0.3A 250V
J44
J48
J1
J2
J24
J45
J49
J15
J16
J47
J13
J27 J25 J26 J23 J33
J28 J30 J31 J32 J29
J12
J46
J20
J57
J8
J14
J22
J21
J56
F5 30A
GND
K3
K5
K6
K2
K1
K4
OZONE
22117_B
RED AC
GND
GND
WHT AC
HTR A
HTR B
UNFUSED
S1
J45
J46
F4 3A 250V
J18
J19
K7
T1
J15
J33
J31 HCE
J30 TST
J27
H3
J22
J26 H2
J25 H1
J17
J16
J29 VAC
J28 AUX FRZ
J5
LIGHT
ON
22121_E
1
6
CONTROL PANEL
TO J33
AUX
TO J5
ALL UNUSED SWITCHES
SHOULD BE OFF
STORE SETTINGS*
SPECIAL AMPERAGE RULE OFF
DON’T ADD 4 HS PUMPS W/HTR
DON’T ADD 2 HS PUMPS W/HTR
DON’T ADD 1 HS PUMP W/HTR
TEST MODE OFF
MEMORY RESET*
SPECIAL AMPERAGE RULE ON
ADD 4 HS PUMPS WITH HEAT
ADD 2 HS PUMPS WITH HEAT
ADD 1 HS PUMP WITH HEAT
TEST MODE ON
6
5
4
3
2
1
ON POSITION
S1 SWITCH #
OFF POSITION
*SWITCH #
6
SHOULD BE SET TO OFF
UPON FINAL INSTALLATION.
SENSOR A
SENSOR B
NOT USED
2S PUMP 1
1S PUMP 2NOT USED
ADDED JUMPER FOR
120VAC HEATER SYSTEM
REMOVE FOR 240V HEATER
GRN
BLK
GFCI
1.0 kW
120v to 240v heater conversion instructions:
1, Conversion must be performed by a qualifi ed, licensed electrician.
2, Disconnect from power and remove power cord.
3, Completely remove jumper wire between J29 and J33 and discard.
4, Install 240V power conductors; Line 1, Line 2 and Neutral to main terminal block (TB1)
Software Confi guration Changes based on Default
Feature
Orig. Setup 1
Changes to
J14, TP600 Button 2, TP400 Button 4, LED 2, AX10A2 . . . . . . . . . Pump 2 . . . . . . . . . . . . . . . . . .
Not Used
Blue indicates changes from the original Setup 1 default
Refer to Page 3 to choose a suitable Plumbing Kit.