53857_02-97_A
Jumper Definitions
Jumpers Key
J29
. . . . . . . . . Jumper on Pins 1 and 2 will power J9-pin 1 (Mister) at 12 Volts AC.
Jumper on Pins 2 and 3 will power J9-pin 1 (Mister) at 120/240 Volts AC.
Note: W4 controls voltage on return line of J9-pin 3 and must be set for the same voltage.
J37
. . . . . . . . . Jumper on Pins 1 and 2 will power one leg of J10-pin 2 (Spa Light) at 120/240 Volts AC.
Jumper on Pins 2 and 3 will power one leg of J10-pin 2 (Spa Light) at 12 Volts AC.
Note: W9 controls voltage on the return line of J10-pin 1 and must be set for the same voltage.
J39
. . . . . . . . . Jumper on Pins 1 and 2 will power J2 pin 2 with Pump 1 Low.
Jumper on Pins 2 and 3 will power J2 pin 2 with the Circ Pump.
Note: W6 controls voltage on common line of J2-pin 3
J47
. . . . . . . . . Jumper on Pins 1 and 2 will power J8 pin 2 (Fiber Optic Light) and J7 at 120/240 Volts AC.
Jumper on Pins 2 and 3 will power J8 pin 2 (Fiber Optic Light) at 12 Volts AC.
Note: J47 and J49 must be set for the same voltage. W5 controls voltage on return line of J8-pin 3 and
must be set to the same voltage.
J49
. . . . . . . . . Jumper on Pins 2 and 3 will power J8 pin 1 (Fiber Optic Wheel) at 120/240 Volts AC.
Jumper on Pins 1 and 2 will power J8 pin 1 (Fiber Optic Wheel) at 12 Volts AC.
Note: J47 and J49 must be set for the same voltage. W5 controls voltage on return line of J8-pin 3 and
must be set to the same voltage.
J91
. . . . . . . . . Jumper on 1 Pin only enables Real Time Clock function, for use with time capable panels.
Jumper on Pins 1 and 2 will disable RTC function, for use with non-time capable panels
.
WARNING:
•
Setting Jumpers incorrectly may cause abnormal system behavior and/or damage to system components.
•
Refer to Jumper illustration in this hot sheet for correct settings for this system.
•
Contact Balboa if you require additional configuration pages added to this hot sheet.