Balanced Audio Technology VK-60 Owner'S Manual Download Page 7

Replacing Fuses: 
 

WARNING:  Please turn the unit OFF and disconnect the power cord before 
proceeding.   
 
There are five fuses in the VK-60.  The main Slow-Blow fuse (10A rating for 110-
120VAC line voltage and 5A for the 200-240VAC range) is located on the unit’s back 
panel.  The four 3A Fast-Acting protection fuses are mounted on the VK-60 printed 
circuit boards and can be acsessed through the holes in the amplifier bottom plate.  If the 
pilot LED on the front panel goes out, try replacing the main fuse on the back panel with 
the same type fuse.   
 
If one or more of the autobias LED’s has gone out, turn the unit off and wait for few 
minutes before proceeding, allowing the internal electrical charge to dissipate.  Place the 
VK-60 on its side and hold securelly.  Through the acsess holes in the bottom plate, 
remove and replace the blown fuse with the 3A Fast-Acting type.   
 
In either case, if the unit still fails to operate properly, please contact the factory for 
professional service. 

 

 

Factory supplied fuses should only be replaced with the same type and rating parts. 

 

 
 
Replacing Output Tubes: 
 

In order to replace the 6C33C-B output tubes, please contact the factory and supply them 
with the unique identification number stamped on the side of the tube needing 
replacement.  This information will be used by Balanced Audio Technology to provide an 
optimal replacement tube for your amplifier. 

 
 

Please do not substitute any random tube as a replacement.  Although the automatic 
bias circuit in the VK-60 will accept virtually any random set of output tubes, the unit 
will not be guaranteed to meet all of its performance specifications under such conditions.  
Finally, the determination that a single tube replacement is prudent rests solely with the 
customer, based on actual hours of use for the particular set of tubes.  The factory 
assumes no responsibility for possible performance decrease under such conditions. 
 

 
 
 
 
 

Summary of Contents for VK-60

Page 1: ...___________________________ Address _______________________________________ _______________________________________ IMPORTANT NOTE In order to receive the full five year product warranty please mail t...

Page 2: ...VK 60 Balanced Power Amplifier Owner s Manual 1300 First State Blvd Suite A Wilmington DE 19804 Tel 302 999 8855 Fax 302 999 8818...

Page 3: ...ous injury electrical shock or fire DO NOT operate with the bottom cover removed DO NOT expose to rain or moisture DO NOT defeat the ground power plug DO NOT replace fuses with anything other than the...

Page 4: ...should you need to replace any 6SN7 tube at a later date no critical matching or number is required Output 6C33C B tubes V9 through V12 can be installed in any of the four output sockets Physical Pla...

Page 5: ...ended preamplifiers connected to its inputs All that is required to connect a single ended preamplifier with RCA connectors to the VK 60 s inputs is the optional balanced to single ended adapters Thes...

Page 6: ...ON again Autobias Feature The VK 60 implements a sophisticated autobias circuit that automatically compensates for tube aging and line voltage fluctuations as well as marginal mismatching of tubes The...

Page 7: ...t Acting type In either case if the unit still fails to operate properly please contact the factory for professional service Factory supplied fuses should only be replaced with the same type and ratin...

Page 8: ...performance Please direct any further service inquiries to the factory Cleaning To remove dust occasionally wipe the front and top surfaces of your VK 60 with a damp soft cloth If fingerprints appear...

Page 9: ...void if the product has been repaired modified or tampered with by anyone other than Balanced Audio Technology or its specifically authorized agents 5 Remedy If this product contains a materials manu...

Reviews: