Balanced Audio Technology VK-51SE Owner'S Manual Download Page 12

 

12

RELATIVE Volume adjustment
 
It is quite common to have sources with very different output levels connected to a preamplifier.  In 
this case, switching between different inputs is usually accomplished by a large change in volume.  
The VK-51SE allows the user to avoid this inconvenience by setting volume offsets between 
different inputs (using ANY input as a reference).   
 
To program this feature: 

 

1.  Select any input that you would like to use as a reference.  Play music at the level you find 

comfortable. 

2.  Press the Function button twice.  The display will read:  VOL    000 
3.  Switch to a different input.  Adjust the volume while playing the music to the level that is 

comparable to the reference input level.  The display will indicate the volume offset 
number.  That number can be either positive or negative, depending upon whether the new 
selected input is stronger or weaker than the reference input. 

4.  Exit the programming mode by pressing and holding the Function button or by switching 

to a different input. 

 
Any input volume offset can be programmed at ANY time with respect to ANY other input.   
 
 

EXAMPLE: 

 

The CD1 input is used as the reference.  Let’s presume that the PH1 input (the weaker source) is 
then programmed to play at 20 counts higher.  Its volume offset will then read 20.   
 
The user can later select the PH1 input and using it as the reference, program the AUX1 input to be 
10 counts lower than the PH1 input.  Effectively, the volume offset from the CD1 input to the 
AUX1 will now become 10. 
 
The user then can at any time verify his volume offset programming by switching the unit in its 
VOLUME mode (by pressing the Function button twice) and then selecting the inputs 3, 4 and 5.  
The volume offset numbers for these inputs should then read 0, 10 and 20 respectfully.  That means 
that the AUX1 source will be played at 10 counts above the CD1 input and the PH1 input at 20 
counts above the CD1 input. 
 

 
 
Alternatively, the volume offset number can be entered directly, based on your judgement of 
volume difference between the two sources.  To do that, select the input, enter the VOLUME 
programming mode by pressing the Function button twice, and use the volume knob to set the 
volume offset number that you deem desirable.  Then exit the programming mode by pressing and 
holding the Function Button

 
NOTE:  A negative number for the selected input indicates that its gain will be set lower than 
the gain of the reference input. 
 
 

Summary of Contents for VK-51SE

Page 1: ..._____________________________ Address _______________________________________ _______________________________________ IMPORTANT NOTE In order to receive the full five year product warranty please mail...

Page 2: ...2 VK 51SE Vacuum Tube Balanced Stereo Preamplifier Owner s Manual 1300 First State Blvd Suite A Wilmington DE 19804 Tel 302 999 8855 Fax 302 999 8818...

Page 3: ...ction 7 VOLUME knob 7 DISPLAY format 8 FUCTION button 8 DISPLAY Brightness Function 9 MUTE function 9 VK 51SE PROGRAMMABLE FUNCTIONS 10 Parameter Definitions 11 PROGRAMMING THE VK 51SE 11 BALANCE adju...

Page 4: ...re DO NOT operate with the cover removed DO NOT expose to rain or moisture DO NOT defeat the ground power plug DO NOT replace fuse with anything other than the same type and rating as supplied by the...

Page 5: ...ve Pin 3 negative Use either the Main 1 or Main 2 Output for connection to your power amplifier Both yield equivalent results Single Ended Components Single ended components have RCA connectors The VK...

Page 6: ...SE On it will automatically go through a gentle power on sequence This sequence takes 50 seconds during which time the display and the Standby LED will be flashing indicating the status of the unit 1...

Page 7: ...me the signal cables are changed or any other system configuration changes are being made This function is also accessible via the VK R3 remote control LED OFF Unit in Play mode LED ON Output Muted IN...

Page 8: ...nels are identical 4 Volume setting three digits with the full range of 000 to 140 See programming section on Maximum Volume Setting FUNCTION Button This button puts the unit in its programming mode I...

Page 9: ...ack ON MUTE Function The VK 51SE has two mute modes manual and automatic The blue LED above the Mute button goes ON when the unit is in MUTE state To MUTE the VK 51SE depress the MUTE button located o...

Page 10: ...o front panel controls the Function button and Volume knob or corresponding remote control buttons Function and Volume Up Down buttons Every unit comes from the factory with a default set of parameter...

Page 11: ...udio Video installations With this flexibility it is possible for example to set the CD input to be Stereo and Non Inverting while the PHONO input would be Mono and Inverting PROGRAMMING THE VK 51SE N...

Page 12: ...input is used as the reference Let s presume that the PH1 input the weaker source is then programmed to play at 20 counts higher Its volume offset will then read 20 The user can later select the PH1...

Page 13: ...Use the volume knob to set the condition to STEREO MONO or LAST Exit the programming mode by pressing and holding the Function button NOTE In the LAST mode the state of the Phase switch will be the s...

Page 14: ...for the VK 51SE preamplifier correspond to the following volume setting CNTS display mode 106 Counts DBU 00 0dB DBM 17 0dB Exit the programming mode by pressing and holding the Function button DISPLA...

Page 15: ...etc To program the input name do the following Select the desired input Press the Function button eight times The first character of the input name will start blinking Use the volume control knob or t...

Page 16: ...or more flexible control when large changes in volume are required Mute Pressing this button will cause the MUTE function in the VK 51SE to toggle between ON and OFF states The Mute LED on the VK 51SE...

Page 17: ...51SE ON With the VK 51SE in its OFF or STANDBY state simply press the POWER button on the VK R3 remote control transmitter Fuse Protection A blown fuse in the VK 51SE is an indication of a serious pro...

Page 18: ...by anyone other than Balanced Audio Technology or its specifically authorized agents 5 Remedy If this product contains a materials manufacturing or workmanship defect that cannot be repaired at the d...

Reviews: