DISPLAY MODE programming 

 

The volume display of the VK-33SE can be switched to work in any of the 

following three modes: 

 

CNTS:   

Relative volume counts with the range of 000 to 140 

 

DBU:    

Decibel readings with respect to unity gain (0dB). 

 

DBM:   

Decibel readings with respect to maximum gain (20dB) 

 

NOTE:  To avoid possible confusion, the SAME display mode setting 

applies to ALL inputs.  It is not possible, for example, to set one 

input to CNTS and another to DBU. 

 

 

 

 

 

 

 

 

 

INPUT NAME programming: 

 

The VK-33SE allows the user to assign any a custom name to any input.  Those 

names may include up to four characters.  The default names for the inputs are as 

follows: 

 

TAPE 

TUN 

CD! 

AUX1 

AUX2 (It will automatically switch to PH1 if the optional phono card is 

installed) 

 

Any combination of up to four Latin, Cyrillic, Greek alphabet characters or digits 

can be used to name the source.  The examples may include: 

 

CD-2, DVD1, JOHN, VKD5, MARY, BOB1, etc. 

 

To program the input name, do the following: 

 

 

Select the desired input 

 

Press the Function button eight times.  The first character of the input name 

will start blinking 

 

Use the volume control knob or the remote control Volume Up/Down buttons 

to select the desired character.  The characters are organized in the following 

Summary of Contents for VK-33SE

Page 1: ..._________________ Address _______________________________________ _______________________________________ Date of Purchase _______________________________________ Purchased From Dealer Name __________...

Page 2: ...ith a copy of your sales receipt to Balanced Audio Technology at the address below within thirty days of purchase Failure to do so will result in the product being warrantied for one year from the dat...

Page 3: ...3 VK 33SE Vacuum Tube Balanced Stereo Preamplifier Owner s Manual 1300 First Stat Blvd Suite A Wilmington DE 19804 Tel 302 999 8855 Fax 302 999 8818...

Page 4: ...tube and provides in our view the best combination of sonic characteristics and electrical performance However the unique design of the VK 33SE allows you to also use other tube types in that applicat...

Page 5: ...screws holding the current source board 3 Pull the current source board straight up to disengage its connectors 4 Install the new current source board making sure its connectors are properly aligned B...

Page 6: ...16 DISPLAY MODE 16 INPUT NAME 17 REMOTE CONTROL FUNCTIONS 18 Volume Up Down 18 Mute 18 Fade 18 Input 18 Display Power 19 Fuse Protection 19 Servicing 19 Cleaning 19 RESETTING THE VK 33SE 20 SPECIFICAT...

Page 7: ...supplied by the factory Package Contents Included in the box should be the following Description Quantity VK 33SE Preamplifier 1 Power Cord 1 Spare Fuse 1 Torx Wrench T 15 1 Spare Top Cover Screws 5 U...

Page 8: ...ve For the VK 33SE use the Main 1 XLR Output for connection to your balanced power amplifier The Output 2 is configured as an RCA connector output Single Ended Components Single ended components have...

Page 9: ...K 33SE Power On sequence When you turn the VK 33SE ON it will automatically go through a gentle power on sequence This sequence takes 50 seconds during which time the display and the Standby LED will...

Page 10: ...ecordings This function is also accessible via the VK R3 remote control LED OFF Stereo operation LED ON Mono operation MUTE Button and LED The Mute button disables the preamplifier output It is recomm...

Page 11: ...ons and can include up to four character from the Latin Cyrillic or Greek alphabets or digits 3 Balance adjustment indicator Characters L or R indicate that the balance is shifted in the corresponding...

Page 12: ...ange i e Volume Input selection Fade will automatically turn the display back ON MUTE Function The VK 33SE has two mute modes manual and automatic The blue LED above the Mute button goes ON when the u...

Page 13: ...rols the Function button and Volume knob or corresponding remote control buttons Function and Volume Up Down buttons Every unit comes from the factory with a default set of parameters stored in its me...

Page 14: ...ximum gain 8 Fixed volume mode this allows any input to be set with a preferred fixed volume setting and is usable for example in Audio Video installations With this flexibility it is possible for exa...

Page 15: ...l indicate the volume offset number That number can be either positive or negative depending upon whether the new selected input is stronger or weaker than the reference input 4 Exit the programming m...

Page 16: ...tton three times The display will read PHASE NINV Use the volume knob to set the condition to NINV INV or LAST Exit the programming mode by pressing and holding the Function button NOTE In the LAST mo...

Page 17: ...o set a particular input to a fixed gain that is then becomes unaffected by the volume knob Most often it is required to set the preamplifier gain to Unity Gain of 1 The VK 33SE allows the user to do...

Page 18: ...custom name to any input Those names may include up to four characters The default names for the inputs are as follows 1 TAPE 2 TUN 3 CD 4 AUX1 5 AUX2 It will automatically switch to PH1 if the option...

Page 19: ...Volume Up and Volume Down control Mute function Fade Down Fade Up function Input Source Selection 1 through 5 Phase switch Function switch Display POWER switch The following describes these functions...

Page 20: ...gain will cause the volume to ramp back up to its initial value INPUT SELECT Pressing any input selection button on the VK R3 remote control will switch the VK 33SE to that input All of the set parame...

Page 21: ...ts 1 5A 250V Slow Blow Factory supplied fuses should be only replaced with the same type and rating parts Servicing The Balanced Audio Technology VK 33SE should require no service in normal operation...

Page 22: ...erase ALL user programmed setpoints and will return the unit to its factory default state In order to RESET the VK 33SE do the following 1 Turn the unit OFF 2 Disconnect the power cord from the back...

Page 23: ...Resolution 5dB Volume Control Number of Steps 140 Frequency Response 2 Hz to 200 kHz Input Impedance minimum 100kOhm each phase Output Impedance 300 Ohm each phase Noise unweighted 96 dB Distortion a...

Page 24: ...h by anyone other than Balanced Audio Technology or its specifically authorized agents 5 Remedy If this product contains a materials manufacturing or workmanship defect that cannot be repaired at the...

Page 25: ...25...

Reviews: