Fuse Protection: 
 
The circuitry of the VK-250 is protected by the following fuses: 
 
1.  The main line fuse is located on the back panel.  This fuse should be checked if the 
front panel LED’s fail to light. 
 
2.  Two internal fuses are mounted on each of the two amplifier circuit boards.  These fuses 
have two green LED’s associated with them.  Both LED’s should be lit when unit is ON and 
operating properly.  Failure of either of these LED’s to light indicates that the corresponding 
fuse is open. 
 

 

CAUTION:

 

 

Make sure that the VK-250 is turned OFF and disconnected from the power line 
before checking or replacing fuses. 

 

 
 
A blown fuse in the VK-250 is an indication of a serious problem.  If a replacement fuse fails 
as well, no further attempts at servicing the unit should be undertaken.  Please contact the 
factory for professional service. 
 
Fuse Ratings 
 
The proper ratings for the main line fuse are as follows: 
 
 

For 100-120 VAC Units: 

 

 

10A 250V Slow Blow 

 
 

For 200-240 VAC Units: 

 

 

7A 250V Slow Blow 

 
The internal printed circuit board mounted fuses are 10A Fast Acting type. 
 
 

 

Factory supplied fuses should be only replaced with the same type and rating parts. 

 

 
 
Servicing 
 
The Balanced Audio Technology VK-250 should not require service to maintain its high 
performance.  In case of malfunction, if replacing fuses fails to eliminate the problem, please 
direct any further service inquiries to the factory. 
 

Summary of Contents for VK-250

Page 1: ...____________________________ Address _______________________________________ _______________________________________ IMPORTANT NOTE In order to receive the full five year product warranty please mail...

Page 2: ...VK 250 Balanced Power Amplifier Owner s Manual 1300 First State Blvd Suite A Wilmington DE 19804 Tel 302 999 8855 Fax 302 999 8818...

Page 3: ...fire DO NOT operate with the cover removed DO NOT expose to rain or moisture DO NOT defeat the ground power plug DO NOT replace fuses with anything other than the same type and rating as supplied by t...

Page 4: ...0 seconds before turning it back ON Power Connection Due to the VK 250 amplifier high power rating it is important to assure the good quality power line connection If separate circuit outlets are used...

Page 5: ...Audio Technology at a nominal charge Input Adapters RCA Female to XLR Male Speaker Connections There are two sets of high quality binding posts on the back panel of the VK 250 one for each channel The...

Page 6: ...s not connected to the external 12V Trigger line its Blue ON indicator will turn ON and OFF when the power switch is depressed When unit is connected to the external controller via the 12V Trigger lin...

Page 7: ...or replacing fuses A blown fuse in the VK 250 is an indication of a serious problem If a replacement fuse fails as well no further attempts at servicing the unit should be undertaken Please contact th...

Page 8: ...horized agents 4 Remedy If this product contains a materials manufacturing or workmanship defect that cannot be repaired at the dealership where the product was purchased it must be packed in original...

Reviews: