background image

DCF 77 RADIO CONTROLLED CLOCK

The remote sensor receives the time signal transmitted by Physikalisch-Technische
Bundesanstalt  (PTB)  of  Germany,  which  is  regulated  by  4  atomic  clocks  and  in

average  deviates  less  than  1  second  in  2  million  years.  PTB  transmits  the  time  signal
(DCF77, 77.5kHz)  continuously  from  Mainflingen,  25  km  southeast  of  Frankfurt  (am

Main).  It  is  expected  that  the  signal  can  cover  a  distance  of  1,500  km  from  the
transmitter. Then the remote sensor transmits the time signal to the weather station to

display the accurate time. However, there are many environment factors may affect
the RCC reception, i.e. nearby computer monitors or other electronic devices, put on

any metal surface, surrounded by any tall buildings and so on. The user had better to
place the remote sensor away from metallic structures and face the transmitter in

Mainflingen-near Frankfurt, Germany.

SET THE CLOCK

Note 2

1. Press and hold the [MENU/SETUP] button for more than 2 seconds to enter clock

setting mode, the hour value begins flashing at the frequency of 1Hz.

2. Press the [ ] or [ ] button once to increase or decrease the hour value by one

hour. Hold down either button will initiate fast increment/decrement (with 10
increments/decrements per second).

3. Press the [MENU/SETUP] button to confirm the hour value. The minute value begins

flashing at the frequency of 1Hz.

4. Press [ ]  or  [ ]  button  to  set  your  desired  minute  value.  Holding  down  either

button will initiate fast increment/decrement (with 10 increments/decrements per

second). Press the [MENU/SETUP] button to confirm the minute value.

Note 3

Note:

2.

If there is no key pressed in the setting mode for 10 seconds, it will automatically save the set value

and exit to normal display.

3.

Every change of minute digit will automatically reset the seconds to zero.

TO SET DAILY ALARM

Note 4

1. In the clock time display mode, press the [ ] button once to switch to display

alarm time for 10 seconds.

2. Press the [ ] button again in alarm display mode to enable or disable the daily

alarm.

3. In the alarm time display mode, press and hold the [ ] button for 2 seconds to

enter the alarm setting mode.

4. The hour digits will be flashing, use the [ ] button to increase by one hour or the

Summary of Contents for LED Weather Station

Page 1: ...LED Weather Station with 433 MHz Remote Sensor User s Manual...

Page 2: ...quipped with a 433MHz radio frequency RF interface it can receive data from up to three remote sensors for outdoor temperature measurement within a distance of 100 feet 30 meters in open space The dat...

Page 3: ...own when the batteries of the remote sensor are running low and the temperature measured by this sensor is no longer reliable The user must change the batteries as soon as possible K Remote sensor ind...

Page 4: ...OCK or ALARM setting mode 7 RESET button Press once to trigger system reset and restore the factory default setting 8 BRIGHT DIM button Toggle to select a bright LED display or a dim LED display GETTI...

Page 5: ...le stand from the weather station Open the battery compartment on the rear of the weather station Install 2 pieces of AAA sized batteries according to the polarity mark inside the battery compartment...

Page 6: ...check the low battery icon in the remote sensor and replace the batteries if necessary Secondly manually re register your remote sensor with below steps Remove the batteries from the remote sensor for...

Page 7: ...de the hour value begins flashing at the frequency of 1Hz 2 Press the or button once to increase or decrease the hour value by one hour Hold down either button will initiate fast increment decrement w...

Page 8: ...e snooze function When the alarm sounds move your hand in front of the IR motion sensor within a distance of 8cm to pause alarm and activate snooze function The alarm bell icon will keep flashing duri...

Page 9: ...mperature range 10 C to 60 0 C 14 F to 140 0 F Operating temperature range 0 C to 50 0 C 32 0 F 122 0 F Temperature resolution 0 1 C 0 2 F Remote Temperature measurement Displayed OUT temperature rang...