background image

INSTALLATION

AND

OPERATING

INSTRUCTIONS

INTENDED FOR OTHER THAN HOUSEHOLD USE

Models:

VH1620E, VHVA1620E, VH1828E & VHVA1828E

RETAIN THIS MANUAL FOR FUTURE REFERENCE

OVEN MUST BE KEPT CLEAR OF COMBUSTIBLES AT ALL TIMES

P/N U4173A 12/05

1

This equipment has been engineered to provide you with year-round dependable service when used

according to the instructions in this manual and standard commercial kitchen practices.

Initial heating of oven may generate smoke or fumes and must be done in a well ventilated area.

Overexposure to smoke or fumes may cause nausea or dizziness.

FOR YOUR SAFETY:

Do not store or use gasoline or other flammable vapors and

liquids in the vicinity of this or any other appliance.

!

!

WARNING:

Improper installation, adjustment, alteration, service or maintenance can

cause property damage, injury or death. Read the Installation, Operating and

Maintenance Instructions thoroughly before installing or servicing this equipment.

!

!

ANSI/NSF4

BAKERS PRIDE OVEN CO., INC

.

30 Pine Street

New Rochelle, NY 10801

(914) 576-0200 Phone

(800) 431-2745 US & Canada

(914) 576-0605 Fax

www.bakerspride.com WebAddress

COUNTERTOP MODEL

ELECTRIC CONVEYOR OVENS

Summary of Contents for VH1620E

Page 1: ...nd must be done in a well ventilated area Overexposure to smoke or fumes may cause nausea or dizziness FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the Installation Operating and Maintenance In...

Page 2: ...SAFETY PRECAUTIONS CAUTION These models are designed built and sold for commercial use If these models are positioned so the general public can use the equipment make sure that cautions warnings and operating instructions are clearly posted near each unit so that anyone using the equipment will use it correctly and not injure themselves or harm the equipment WARNING Check the data plate on this un...

Page 3: ...ply with CSA STANDARD C 22 2 Number 0 M1982 General Requirements Canadian Electrical Code Part II 109 M1981 Commercial CookingAppliances NOTICE Local codes regarding installation vary greatly from one area to another The National Fire Protection Association Inc states in its NFPA96 latest edition that local codes are Authority Having Jurisdiction when it comes to requirements for installation of e...

Page 4: ... 3 Phase 29 E VH 1620E Schematic 208 220 or 240VAC 1 Phase 30 F VH 1620E Wiring Diagram 208 220 or 240VAC 1 Phase 31 G VH 1620E Schematic 208 220 or 240VAC 3 Phase 32 H VH 1620E Wiring Diagram 208 220 or 240VAC 3 Phase 33 I VHVA 1828E Schematic 208 220 or 240 1 Phase 34 J VHVA 1828E Wiring Diagram 208 220 or 240 1 Phase 35 K VHVA 1828E Schematic 208 220 or 240 3 Phase 36 L VHVA 1828E Wiring Diagra...

Page 5: ...INSTRUCTIONS 1 RECEIVING 2 LOCATION AND MINIMUM CLEARANCES VH1620E 6 4 1 or 3 VHVA1620E 6 4 1 or 3 VH1828E 12 4 1 or 3 VHVA1828E 12 4 1 or 3 Read the notice on the outside carton regarding damage in transit CONCEALED DAMAGE damage discovered after opening the crate s MUST be reported immediately to the carrier The carrier will perform an inspection of the damage and furnish forms for the consignee...

Page 6: ... supplied with a flexible power cord and plug Your conveyor oven s can be stacked up to 3 high Each unit is built exactly the same so it does not matter in which order they are stacked For stacking of 2 units remove the legs from the second upper unit prior to mounting on top of the bottom unit For stacking of 3 units it is preferable to use a stacking kit which allows all conveyor ovens to be sup...

Page 7: ...EMENTS THE CORRECT CONVEYOR OVEN MUST BE INSTALLED THE CONVEYOR OVEN CANNOT BE MODIFIED IN THE FIELD TO MATCH INPUT POWER CAUTION VERIFY VOLTAGE OF EACH LEG IF ANY LEG HAS A VOLTAGE GREATER THAN 240V THIS LEG MUST BE CONNECTED TO L 3 ON THE POWER DISTRIBUTION BLOCK FOR DUALAIR MODELS VH1620E VHVA1620E FOR DUALAIR MODELS VH1828E VHVA1828E FOR 3 PHASE UNITS ONLY These units are supplied with a flexi...

Page 8: ...unit Direction of travel is controlled by a Reversing Switch that is located inside the control box containing the gearmotor If the direction of travel needs to be reversed follow this procedure 1 2 Reversing the conveyor belt requires opening the Power Control Box door 3 Locate a small rocker switch mounted just inside the control box either black or orange in color Two wires are connected to it ...

Page 9: ... DOWN until they are in the correct position to allow product to enter and exit with minimal vertical clearance This will reduce the amount of heat lost out the sides of the cook chamber 9 REMOVABLE PLENUM FINGERS ASSEMBLY ALL FOUR IDENTICAL UPPER AIR RETURN SHIELD LOWER AIR RETURN SHIELD ASSEMBLY INTERNAL FIXED AIR PLENUM ASSEMBLIES END SLOTS TOWARDS ADJUSTABLE BAFFLE 1 4 TURN FASTENERS 2 TOP 2 B...

Page 10: ...ooking process 8 I O IF THE MAIN SWITCH IS TURNED OFF DURING INITIAL START UP LEAVE UNIT OFF FOR AT LEAST 15 SECONDS TO ALLOW THE AIR VELOCITY CONTROLS TO RESET TOGGLING THE SWITCH RAPIDLY ON OFF WILL STALL THE BLOWER MOTORS AND ALLOW THE HEATERS TO COME ON EVEN THOUGH NO AIR WILL BE MOVING THIS CAN DAMAGE THE UNIT 5 Reduce the blower speed by turning the knob half way Counter clockwise until indi...

Page 11: ...the belt assembly out the side E INDEPENDENT TOP AND BOTTOM OUTER SIDE COVERS Makes it possible to remove conveyor belt from the front F SYMMETRICAL OUTER COVERS DUAL AIR 1828E ONL Y T op and bottom outer side covers can mount on either side G EASE IN CLEANING This is accomplished by easily removable components for access to the cook chamber air plenum fingers and conveyor belt assembly The unit h...

Page 12: ...rd construction of the interior cook chamber is of aluminized steel and requires care not to over clean and scratch the surface Use only the detergent solutions and cleaners that meet national and or local codes Clean the walls of the cook chamber with a mild soap and water solution T o clean the interior of the conveyor oven it is necessary to remove the front door the 4 outer sides panels the co...

Page 13: ...ke the main cook chamber and thus requires the same level of care to retain its integrity Follow the same precautions as mentioned above for the main cook chamber UPWARD 11 OPERATOR MAINTENANCE WARNING DANGER DISCONNECT THE POWER SUPPLY BEFORE SERVICING OR CLEANING THE OVEN SERIOUS INJURY INCLUDING DEATH MAY OCCUR IF CONTACT IS MADE WITH INCOMINGPOWER During normal operation of the oven lubricatio...

Page 14: ...s OFF if there is excessive current going to the motor s or if excessive heat builds up in the overload relay due to an overload condition Because it takes time for the relay to cool down do not assume that there is another problem IF pushing the RESET button doesn t accomplish the task Both settings must be correct for proper operation If the conveyor belt does not move check to see that the coup...

Page 15: ...H VHV A Series ovens the outer upper and lower covers are symmetrical and can be mounted on either side of the oven e Open the front hinged door f Carefully supporting both right and left sides of the conveyor lift the front edge slightly and pull towards you watching as the drive shaft pulls out of the gearmotor coupling Installing the conveyor belt assembly is done in exact reverse order to it s...

Page 16: ... time 2 For a cook time of 6 minutes the required time to pass between timing marks would be 6 minutes x 60 seconds 4 This equals 360 seconds 4 90 seconds between marks The belt needs to take 90 seconds 1 1 2 minutes to move from one mark to the next to equal a 6 minute cook time E Using a black marking pen mark any belt link near the outer edge Using a stopwatch check the time it takes for this l...

Page 17: ...product Time of Delivery Trailing Edge of Product Time of delivery will be different for different sizes of products Time of Delivery TOD X Bake Chamber Length Product Diameter Bakers Pride 6 Minute Bake Time 16 pizza time required for the 1st item TOD X 20 16 10 8 Minutes Example 1 Dual Air Model 1620 Bake Time Bake Chamber Length 6 Minutes 20 6 Minutes 28 Example 2 Dual Air Model 1828 Bakers Pri...

Page 18: ...le tensioner at one end of belt frame Properly re attach and tighten to gearmotor output shaft Remove belt assembly to identify obstruction to belt movement Remedy problem Straighten bent belt links Tighten setscrew to gearmotor output shaft shaft is flatted for setscrew grip Align and engage shaft pin to slot in drive coupling Install master link s properly Turn ON Plug cord in 1620E only CAUTION...

Page 19: ...trols to minimum then adjust each one separately to hear for sound changes which indicate air movement model VHVA Series only THE PROBLEM THE CAUSE THE SOLUTION No air or not enough air coming from blower s Verify correct rotation counterclockwise when standing in front of machine Remove the front door the conveyor belt assembly and both upper and lower air return shilelds Turn the Main Switch ON ...

Page 20: ...and speed control at the header terminal on speed control board 4 One pot wire contains a 15K ohm resistor at the pot body Verify this solder connection is good Blower speed control s failed 5 Blower s can stop if speed controls have not been reset model VHVA Series only If yellow FAULT light on speed control circuit board is ON first turn OFF main Switch for 15 seconds to rest control s If yellow...

Page 21: ...working properly THE PROBLEM THE CAUSE THE SOLUTION NOTE temperature sensor lead wires are NOT polarity sensitive since sensor is an RTD type 4 If resistance reads value within range of chart sensor is good control needs further investigation Re connect sensor wire leads See diagram at back of manual for proper identification of controls 5 If both sensors are good swap sensor leads between control...

Page 22: ...22 Notes ...

Page 23: ...24 1753 400 1046 54 1411 230 1761 404 1059 60 1420 234 1773 410 1067 64 1432 240 1781 414 1080 70 1440 244 1793 420 1088 74 1452 250 1801 424 1101 80 1460 254 1813 430 1109 84 1473 260 1821 434 1122 90 1481 264 1832 440 1130 94 1493 270 1844 446 1143 100 1501 274 1852 450 1151 104 1513 280 1860 454 1164 110 1521 284 1872 460 1172 114 1533 290 1879 464 1184 120 1541 294 1891 470 1193 124 1554 300 1...

Page 24: ... 18 GA 5 PROBE PROBE 240 VAC 240 VAC VAC COM VAC COM 18 Solid State Relay Labeling I D Models VH VHVA1620E Conveyor Ovens Circuit Leads 208 Volt 240 Volt Between C L3 28 3 Ohms 38 9 Ohms Between D L2 28 3 Ohms 38 9 Ohms Between C D 1 2M Ohms 1 3M Ohms Between C F 1 2M Ohms 1 3M Ohms Between D F 42 3 Ohms 58 1 Ohms Between F L2 14 5 Ohms 19 5 Ohms Three Phase Units Circuit Leads 208 Volt 240 Volt B...

Page 25: ...VAC COM VAC COM Element Resistance Chart VH VHVA Series Conveyor Oven 208 VOLTS 220 VOLTS 240 VOLTS ELEMENT WATTAGE MODEL 14 4 ohms 16 1 ohms 28 8 ohms 32 3 ohms 38 4 ohms 19 2 ohms VH VHVHA1828E VH VHVHA1620E 1500 3000 Circuit Leads 208 Volt 240 Volt Between C L3 14 5 Ohms 18 2 Ohms Between D L2 14 3 Ohms 18 2 Ohms Between C D 4 7M Ohms 3 4M Ohms Between C F 4 7M Ohms 3 4M Ohms Between D F 21 4 O...

Page 26: ...PERATURE CONTROL LOWER TEMPERATURE CONTROL 10 GA GREEN YELLOW STRIPE 18 GA GREEN YELLOW STRIPE 18 GA GREEN YELLOW STRIPE 15 K OHM RESISTOR 15 K OHM RESISTOR 1 2 3 COOLING FAN IN CONTROL BOX DOOR C N O FAN RELAY BROWN 15 BLUE 38 24 23 WHITE BLACK 40 42 SSR 1 BOTTOM ELEMENTS LEFT RIGHT 1500 WATTS EACH REAR EXHAUST FANS SSR 3 TOP ELEMENTS LEFT RIGHT SSR 2 A E B F G C D I J K H A 10 GA BLACK BLACK 10 ...

Page 27: ...WER MOTOR 18 GA BLUE BLUE J 18 GA BROWN 18 GA BLUE J J 18 GA GRAY BLUE B R O W N BLACK AIR PULLED INTO CONTROL BOX G 1 G 2 7 6 4 5 5 4 9 8 4 6 B 1 B 2 B3 21 2 2 A 1 A 2 A 3 9 8 1 8 17 29 30 26 25 2 7 2 8 34 3 4 3 0 G 4 A 25 2 6 G3 G 2 G 4 G 4 ITEMS LOCATED IN CONTROL BOX ENCLOSURE ITEMS LOCATED IN BLOWER COMPARTMENT J BROWN 14 GA L2 E BLUE K WHITE E BLACK L1 10 GA BROWN WHITE WHITE BLACK L1 18 GA ...

Page 28: ...1 43 BLUE ELEMENT CONTACTOR 6 7 8 9 10 11 UPPER TEMPERATURE ADJUSTMENT POTENTIOMETER 3 1 2 5 4 RTDSENSOR YELLOW ORANGE PURPLE GRAY COOLING FAN IN CONTROL BOX YELLOW ORANGE PURPLE CAUTION L1 L2 INPUTS MUST BE 100 125 VOLT POTENTIAL IF A HIGH VOLTAGE LEG GREATER THAN 125 VOLTS IS PRESENT IT MUST CONNECT TO L3 YELLOW WHITE BLACK BLACK UPPER BLOW ER M OT OR S PEED CONT ROL AND POTENT IOMET ER YELLOW Y...

Page 29: ...WER MOTOR 18 GA BLUE BLUE J 18 GA BROWN 18 GA BLUE J J 18 GA GRAY BLUE B R O W N BLACK AIR PULLED INTO CONTROL BOX G 1 G 2 7 6 4 5 5 4 9 8 46 B1 B 2 B 3 21 22 A 1 A 2 A3 9 8 18 17 29 30 26 25 27 28 34 34 30 G 4 A 25 26 G3 G 2 G 4 G4 ITEMS LOCATED IN CONTROL BOX ENCLOSURE ITEMS LOCATED IN BLOWER COMPARTMENT J BROWN 14 GA L2 E BLUE K WHITE E BLACK L1 10 GA BROWN WHITE WHITE BLACK L1 18 GA WHITE L2 1...

Page 30: ...UE INPUT OUTPUT GEARMOTO R POWER SUPPLY RED BLACK 2 46 39 41 WHITE 12 16 14 GRAY A 29 11 19 WHITE 13 19 BLACK POWER BLOCK LO WER TEMPERATURE ADJUSTMENT PO TENTIOMETER 3 1 2 5 4 RTDSENSOR C1 43 BLUE 6 7 8 9 10 11 UPPER TEMPERATURE ADJUSTMENT PO TENTIOMETER 3 1 2 5 4 RTDSENSOR YELLOW ORANGE PURPLE GRAY COOLING FAN IN CONTROL BOX YELLOW ORANGE PURPLE 23 WHITE CO NTACTOR OVERLO AD RELAY L2 L1 WHITE BL...

Page 31: ... 10 GA BLUE 18 GA 31 42 BLACK 22 GA 2PLCS RED BLACK RED 24VDC OUTPUT 44 37 39 41 18 17 20 18 GA GRAY TO TERMINAL BLOCK 4 BLACK ITEMS LOCATED ON MAIN CONTROL BOX DOOR 32 36 29 38 14 GA HIGH TEMP FROM POWER SUPPLY YELLOW YELLOW ORANGE PURPLE ORANGE PURPLE LOWER UPPER ELEMENT CONTACTOR 43 BLUE WHITE 14 GA WHITE 14 GA WHITE 14 GA BROWN 14 GA BLUE 18 GA N P Q M BLACK18 GA CONTACTOR OVERLOAD RELAY BLUE ...

Page 32: ...A 29 11 19 WHITE 13 19 BLACK POWER BLOCK LOWER TEMPERATURE ADJUSTMENT POTENTIOMETER 3 1 2 5 4 RTDSENSOR C1 43 BLUE ELEMENT CONTACTOR 6 7 8 9 10 11 UPPER TEMPERATURE ADJUSTMENT POTENTIOMETER 3 1 2 5 4 RTDSENSOR YELLOW ORANGE PURPLE GRAY COOLING FAN IN CONTROL BOX YELLOW ORANGE PURPLE 23 WHITE CONTACTOR OVERLOAD RELAY 24 B L A C K CAUTION L1 L2 INPUTS MUST BE 120 125 VOLT POTENTIAL IF A HIGH VOLTAGE...

Page 33: ...8 GA GRAY TO TERMINAL BLOCK 4 BLACK ITEMS LOCATEDONMAINCONTROL BOX DOOR 32 36 29 38 14 GA HIGH TEMP 18 GA BLUE 18 GA BROWN 18 GA BROWN 18 GA BLACK 18 GA WHITE FROM POWER SUPPLY YELLOW YELLOW ORANGE PURPLE ORANGE PURPLE LOWER UPPER ELEMENT CONTACTOR 43 BLUE WHITE 14 GA WHITE 14 GA WHITE 14 GA BROWN 14 GA BLUE 18 GA N P Q M BLACK18 GA CONTACTOR OVERLOAD RELAY BLUE18 GA 31 18 GA BROWN 20 24 WHITE 18 ...

Page 34: ...G RE EN YE L L OW S TRIP E LOWER TEMPERATURE C ONTROL UPPER TEMPERATURE C ONTROL G2 G 3 GRN YLW GRAY BRN BLUE BLUE BROWN J J J J J BROWN GRY BR OWN GREEN YELLOW STRIPE BLUE BROWN BLACK 34 28 27 25 33 35 30 32 36 G 2 G 4 17 G2 25 37 26 22 21 19 20 50 10 A GEA RMOTOR R EVER SIN G SWITCH GEARMOTOR AND SPEED POT GREEN YELLOW ORAN GE C O I L C O I L C O I L S S R3 S S R2 S S R1 11 10 9 8 7 6 RED S1 BLK...

Page 35: ...UE BLUE J 18GA BROWN 18 GA BLUE J J 18 GA GRAY BLUE B R O W N BLACK AIR PULLED INTO CONTROL BOX G1 G 2 7 6 4 5 5 4 9 8 4 6 B1 B2 B 3 2 1 22 A 1 A 2 A3 9 8 18 17 29 3 0 26 25 2 7 28 34 3 4 30 G4 A 25 26 G 3 G 2 G 4 G 4 ITEMS LOCATED IN CONTROL BOX ENCLOSURE ITEMS LOCATED IN BLOWER COMPARTMENT J BROWN 14 GA L2 E BLUE K2 WHITE E BROWN WHITE WHITE BLACK L1 18 GA WHITE L2 14 GA WHITE L2 14 GA GREEN 10 ...

Page 36: ...TIOMETER BLAC K 19 13 WHITE 19 11 29 A GRAY 14 16 12 WHITE 41 39 46 BLACK 2 RED GEARMOTOR POWER SUPPLY OUTPUT IN PUT BLUE 31 WHITE 10 GA BROWN BLACK 10 GA BLACK A B E A SSR 2 SSR 3 REAR EXHAUST FANS SSR 1 42 40 38 BLUE 15 FA N RELAY COOL DOWN T STA TS CLOSE ON TEMP RISE N O C COOLING FA N IN CON TROL BOX D OOR 1 2 3 1 8 G A GR E EN YE L L OW ST RIP E 1 8 G A GR E EN YE L L OW S TRIP E 10 G A G RE ...

Page 37: ... 7 6 4 5 5 4 9 8 46 B1 B 2 B 3 21 22 A 1 A 2 A3 9 8 18 17 29 30 26 25 27 28 34 34 30 G 4 A 25 26 G3 G 2 G 4 G4 ITEMS LOCATED IN CONTROL BOX ENCLOSURE ITEMS LOCATED IN BLOWER COMPARTMENT J BROWN 14 GA L2 E BLUE K WHITE E BLACK L1 10 GA BROWN WHITE WHITE BLACK L1 18 GA WHITE L2 14 GA WHITE L2 14 GA GREEN 10 GA L2 L2 3 2 1 18 GA BROWN 18 GA BLUE 18 GA BROWN 18 GA WHITE 18 GA BLACK TO REMOTE POT TO RE...

Page 38: ... TO POWER BLOCK POWER BLOCK JUNCTION BLOCK BLACK WHITE GREEN B SSR 2 SSR 1 30 A MP 30 AMP 10 GA BROWN 10 GA BLAC K 20 BROWN 24 WHITE 23 COOLING FA N IN CONTROL BOX POWER BLOCK BLAC K 19 13 WHITE 19 11 14 16 12 WHITE BLACK A E A SSR 3 REAR EXHAUST F ANS 42 40 38 BLUE 15 FA N RELAY COOL DOWN T STA TS CLOSE ON TEMP RISE N O C 1 8 G A GR E EN YE L L OW ST RIP E 1 8 G A GR E EN YE L L OW S TRIP E 10 G ...

Page 39: ... 18 GA BROWN 18 GA BROWN 18GA BLACK 18 GA WHITE TEMPERATURE CONTROL POTS YELLOW YELLOW ORANGE PURPLE ORANGE PURPLE LOWER UPPER ELEMENT CONTACTOR 43 BLUE WHITE 14 GA WHITE 14 GA WHITE 14 GA BROWN 14 GA BLUE 18 GA N P Q M BLACK18 GA CONTACTOR OVERLOAD RELAY BLUE 18 GA 31 18GA BROWN 20 24 WHITE 18GA 19 WHITE 18GA 23 TO TERMINAL BLOCK 2 BLOWER MOTORS BLACK18 GA WHITE 18 GA 21 22 L1 L2 L1 WHITE 18 GA B...

Page 40: ...RMOTOR POWER SUPPLY RED BLACK 2 46 39 41 WHITE 12 16 14 GRAY A 29 11 19 WHITE 13 19 BLAC K LOWER TEMPERATURE A DJUSTMEN T POTENTIOMETER 3 1 2 5 4 RTDSENSOR C1 43 BLUE 6 7 8 9 10 11 UPPER TEMPERATURE A DJUSTMEN T POTENTIOMETER 3 1 2 5 4 RTDSENSOR YELLOW ORANGE PU RPLE GRAY COOLING FA N IN CONTROL BOX YELLOW ORANGE PU RPLE 23 WHITE C ONTACTOR OVERLOA D RELAY L2 L1 TO TERMINA L BLOC K 1 WHITE BLAC K ...

Page 41: ...OCK 4 BLACK ITEMS LOCATED ON MAIN CONTROL BOX DOOR 32 36 29 38 14 GA HIGH TEMP 18 GA BLUE 18 GA BROWN 18 GA BROWN 18GA BLACK 18 GA WHITE TEMPERATURE CONTROL POTS YELLOW YELLOW ORANGE PURPLE ORANGE PURPLE LOWER UPPER ELEMENT CONTACTOR 43 BLUE WHITE 14 GA WHITE 14 GA WHITE 14 GA BROWN 14 GA BLUE 18 GA N P Q M BLACK 18 GA CONTACTOR OVERLOAD RELAY BLUE 18 GA 31 18GA BROWN 20 24 WHITE 18GA 19 WHITE 18G...

Page 42: ...620E 1828E Item Part Number Description Quan 1 B6546T B7227T Complete conveyor assy with wire belt 1 2 S3268U S3266U Idler shaft assy complete w sprockets 2 3 B6068U B6068U Bearing clip assy 6 4 S3254A S3254A Plastic bearing 6 5 Q4045A Q4045A Drive pin in drive shaft 1 6 S3269U S3267U Drive shaft assy complete w sprockets 1 7 S3252A S3253A Complete wire belt assembly 1 8 S3258A S3259A Wire belt ma...

Page 43: ... 1828E Item Part Number Description Quan 1620E 1828E Item Part Number Description Quan 1620E 1828E Item Part Number Description Quan 1 M1541U M1537U Complete Blower Assy VH 1 or 3 Ph 1 2 3 M1542U M1511U Complete Blower Assy VHVA 1 or 3 Ph 1 4 M1515A M1510A Main Blower Wheel 1 5 S3260A S3260A Minor Wheel Heat Slinger 2 6 M1548A M1548A Blower Motor 1 4 HP VH 1 or 3 Ph 2 M1511A M1511A Blower Motor 1 ...

Page 44: ...oor Assy Complete w items 16 21 23 Hinged Door Only Bare Gearmotor Coupling Gearmotor Adjustment Plate Gearmotor Adapter Plate Gearmotor Belt Conveyor Drive Power Distribution Terminal Block 1620 Uses 1 1828 Uses 2 Gearmotor Power Supply Fuseholder w Cap Fuse SC 5 Amp Gearmotor Reversing Switch Reversing Switch Mounting Bracket Terminal Block Solid State Relay Thermal Pad Temperature Control Cooli...

Page 45: ...B6237T B6237U B6236U U1370A U1366A U1369A U1365A P1008A P1007A Main Switch Indicator Light On for Heat Demand Knob Potentiometer Conveyor Belt Speed Adjust Potentiometer Air Blower Speed Adjust Potentiometer Air Temperature Control Relay Terminal Block Fan Guard Cooling Fan Electric Control Box w items 8 9 11 12 Electric Control Box Only Hinged Door Assy Door Label VH1620E Door Label VH1828E Door ...

Page 46: ...518A M1518A M1518A M1518A M1518A M1518A M1518A M1518A T emperature Sensor Probe 2 2 3 4 L1181A L1189A L1207A L1183A L1185A L1191A L1209A L1187A Heating Element Left Hand 2 L1182A L1190A L1208A L1184A L1186A L1192A L1210A L1188A Heating Element Right Hand 2 M1534A M1534A M1534A M1534A M1534A M1534A M1534A M1534A Cool Down Thermostat 2 Item 2 2 1 3 4 3 4 ...

Page 47: ...atingplateaffixedtotheequipment hasnotbeendefaced orremoved WHO IS COVERED This warranty is extended to the original purchaser and applies only to equipment purchased for use in the U S A COVERAGE PERIOD Cyclone Convection Ovens Two 2 Yearlimited partsandlabor 5 Yearlimited doorwarranty AllOtherProducts One 1 Yearlimited partsandlabor Warranty period begins the date of dealer invoice to customer o...

Page 48: ...48 F BAKERS PRIDE BAKERS PRIDE OVEN CO INC 30 Pine Street New Rochelle NY 10801 914 576 0200 Phone 800 431 2745 US Canada 914 576 0605 Fax www bakerspride com Web Address ...

Reviews: