background image

I.  INSTALLATION INSTRUCTIONS

  Section       Item

         Page

A

Receiving

2

B

Set Up / Mounting

2

C

Installation with Casters

 (Optional)

3

D

Location & Minimum Clearances

4

E

Gas Connections

4

F

Electrical Connection

5

G

Flue Connection  Ventilation

5

H

Burner Operation

5

I

System Check

 Rotary Control

5

J

Programming Menus

6

II.  OPERATING INSTRUCTIONS

A

General Instructions

6

B

Operation Sequence

 Rotary Control

6

Cook only

 Rotary Control

6

2

I.  INSTALLATION INSTRUCTIONS

A. RECEIVING

Read the notice on the outside carton regarding damage in transit. Damage discovered after opening the 
carton  is  “CONCEALED  DAMAGE.”  Carrier  must  be  notified  immediately  to  send  an  inspector  and  to 
furnish forms for claims against the carrier.

When the oven arrives, it should consist of:

!

A crate or carton containing your new oven (two for a stacked unit).

!

A carton containing four 31” legs with mounting hardware (set of four 6” legs is supplied for stacked 
installations).

!

A carton containing a Flue Adapter and a Draft Hood. Optional: for Direct Venting (Not available for 
European Community Countries).

B. SET UP / MOUNTING:

NOTE:

This appliance must be installed by competent personnel in accordance with the rules in force.

In the U.K., Corgi registered installers (including the regions of British Gas) undertake to work to safe and 
satisfactory  standards.  This  appliance  must  be  installed  in  accordance  with  the  current  Gas  Safety 
(Installation  and  Use)  Regulations  and  the  relevant  Building  Regulations/IEE  Regulations.  Detailed 
recommendations are contained in the British Standard Codes of Practice B.S. 6172, B.S. 5440: Part 2 and 
B.S. 6891.

Your oven will be packed sitting on its bottom. The skid may be left under the oven for convenience in further 
handling. Unpack carefully, avoiding damage to the Stainless Steel front and/or trim. If concealed damage 
is found, follow the instructions detailed in Section A (Receiving). Keep the area around the ovens free and 
clear of  combustible materials. Do not store any materials on top of or under any oven. The provision for 
adequate air supply to your oven for ventilation and proper gas combustion is essential. As a minimum, 
observe the clearances detailed in Section D (Location). Provide adequate ventilation and make up air in 
accordance with local codes. Servicing your oven is done through the front control panel and right side 
access cover. Ensure that these areas are kept unobstructed for easy access.

In MASSACHUSETTS: 

All gas products must be installed by a “Massachusetts” licensed plumber or gas 

fitter. Ventilation hoods must be installed in accordance with NFPA-96, current edition, with interlocks as 
described in that standard.

INDEX

  

Section

Item

 

Page

Timed Cooking

 Rotary Control 

    

6

Cook and Hold

 Rotary Control

7

Optional Steam Injection

 Rotary Control

7

To Cool Down the Oven Quickly

7

C

Cleaning

7

D

Servicing

8

Stacking Instructions

9

Leg Assembly Instructions

9

Wiring Diagrams

10

Helpful Hints

12

Troubleshooting Chart

12

Parts List & Exploded View

13

Warranty

                              

16

Summary of Contents for Cyclone BCO-G1

Page 1: ...urces of ignition since these methods are extremely dangerous Instructions to be followed in the event you smell gas should be posted in a prominent location Obtain these instructions from your local...

Page 2: ...tallation and Use Regulations and the relevant Building Regulations IEE Regulations Detailed recommendations are contained in the British Standard Codes of Practice B S 6172 B S 5440 Part 2 and B S 68...

Page 3: ...ust be placed into the hole on top of the oven C INSTALLATION WITH CASTERS OPTIONAL Refer to Figure 4 Four casters two with wheel brakes and the mounting hardware are packed and included in the shipme...

Page 4: ...er For Natural gas use 19 mm pipe The gas pressure regulator is part of the combination valve and is adjusted to yield a pressure of 3 5 water column 9 mbar for Natural Gas If the oven is ordered for...

Page 5: ...esign and the installation of the hood conform to local municipal codes In the U K follow ventilation requirements as detailed in B S 5440 Optional direct venting not available for European community...

Page 6: ...tronic Temperature Control and Electronic Hot Surface Direct Ignition System 2 Due to increased efficiency of this oven the temperature of standard recipes may be reduced 50 F 30 C 3 Always load each...

Page 7: ...down Rotary control To cool down the oven to a lower desired temperature follow the steps detailed below 1 Open the oven doors 2 Turn Selector Switch to oven cool down position Fan will now operate an...

Page 8: ...rub cleanser on the metal in the direction of the polished lines on the metal Rubbing cleanser as gently as possible in the direction of the polished lines will not mar the finish of the stainless st...

Page 9: ...Oven Leg 2 8633515 Foot Insert Adjustable 3 8227700 Hex Hd 5 16 18 X 3 4 Bolt 5 Zn 4 8509300 Washer Flat SAE 5 16 5 8435000 Hex Nut 5 16 18 6 82447 00 Hex Hd 3 8 16 X 750 5 1 Attach four item 2 to fou...

Page 10: ...21 16 19 20 17 18 35 29 11 20 26 34 10 1 7 3 9 BUTT SPLICE L1 24VAC GROUND FLAME SENSE VALVE HOT THERMOSTAT IGNITOR 22 40 41 BUTT SPLICE GROUNDSTUD 3 2 1 4 26 IGNITION CONTROL 7 6 4 3 2 1 GROUND STUD...

Page 11: ...35 29 11 20 26 34 10 1 7 3 9 BUTT SPLICE L1 24VAC GROUND FLAME SENSE VALVE HOT THERMOSTAT IGNITOR 22 40 41 GROUND STUD 3 2 1 4 26 IGNITION CONTROL 7 6 4 3 2 1 Plug or Connection Supplied at installat...

Page 12: ...High Speed Set fan to Low Speed Flame Sensor defective Meats are well done and not browned Bake longer or raise oven temperature slightly Do not open doors to oven for long periods Oven cycles 3 times...

Page 13: ...10801 914 576 0200 914 576 0605 1 800 431 2745 www bakerspride com fax US Canada web address BAKERS PRIDE Cyclone SERIES 4 05 Note When ordering ALWAYS specify Part Model Serial Voltage Phase type of...

Page 14: ...5A KIT CONVERSION TO LP E8766A KIT CONVERSION TO NAT Part Description 1 33 0 34 5 4 12 2 3 30 8 10 11 28 29 9 32 31 27 17 26 20 19 24 7 22 18 13 25 21 14 15 16 23 39 44 45 37 47 74 73 67 50 49 40 46 4...

Page 15: ...R3165A VALVE COMBINATION NAT VALVE COMBINATION L P 1 1 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 N5019A E81...

Page 16: ...eriod of THREE MONTHS The installation of these replacement decks is the responsibility of the purchaser The extended Cyclone door warranty years 3 through 5 is a parts only warranty and does not incl...