background image

XX & CH CHARBROILER OPERATION MANUAL

9

VALVE ASSEMBLY VIEWS

Valve Assembly Views:

Figure 2: Air Mixer Cap And Pilot Burners

Figure 3: Side View - CH Series

(A=Cap Hold-Down Screw)

Figure 3: Side View - XX Series

Summary of Contents for CH-4 XX-4

Page 1: ...BUILT BY CRAFTSMEN TESTED BY TIME SERIES XX CH OPERATION MANUAL DANTE SERIES GAS CHARBROILERS...

Page 2: ...installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servici...

Page 3: ...ION GUIDE 7 TROUBLESHOOTING GUIDE 7 BURNER FLAME ADJUSTMENT 7 PILOT FLAME ADJUSTMENT 7 LACK OF HEAT 7 ONE BURNER FAILS TO LIGHT 8 TROUBLESHOOTING CHART 8 VALVE ASSEMBLY VIEWS 9 PARTS LISTS EXPLODED VI...

Page 4: ...in non combustible locations only including above the grate level Minimum Clearance From Non Combustible Construction Series Right Left Back XX 0 0 0 CH 0 0 0 For units using propane gas supply lines...

Page 5: ...er has a standing pilot burner that must be lit before the burners can be lit To light the pilot burners a Turn all broiler valves to the off position b Remove each top grate and radiant c Open main g...

Page 6: ...e that complies with the latest edition of the Standard for Quick Disconnect Devices for use with gas fuel ANSI Z21 41 in USA CAN 1 6 7 in Canada and adequate means must be provided to limit the movem...

Page 7: ...efore broiling will compensate for the shrinkage Broil a hamburger as you would broil a steak 1 Be sure that the charbroiler has had adequate pre heating time so that the hamburger does not stick to t...

Page 8: ...e flare up trimming excess fat for a longer broil time without burning e Keep the unit clean Food caught between the grates will not allow hot air to rise around the product This will result in uneven...

Page 9: ...air into the burner until the flame turns blue Tighten the screw Pilot Flame Adjustment The pilot flame can be adjusted by turning the appropriate adjusting screw using a screwdriver or a 3 16 wrench...

Page 10: ...ugh to clear the burner orifice fig 3 or 4 Using a thin wire or pin check to see that the orifice is clear taking care not to enlarge the hole Replace the burner radiant and grate and attempt to light...

Page 11: ...XX CH CHARBROILER OPERATION MANUAL 9 VALVE ASSEMBLY VIEWS Valve Assembly Views Figure 2 Air Mixer Cap And Pilot Burners Figure 3 Side View CH Series A Cap Hold Down Screw Figure 3 Side View XX Series...

Page 12: ...r Only C I 24 w Mixer Cap XX O S 18 R3022X Air Mixer Cap w Screw C I Burner only 19 H1008X Grease Guard Only C I Burner 20 T1007A Radiant Cast Iron 23 Optional Shown 21 T1155T Radiant S S 23 Standard...

Page 13: ...XX CH CHARBROILER OPERATION MANUAL 11 PARTS LISTS AND EXPLODED VIEWS EXPLODED VIEW XX 4 6 8 10 12 Exterior Grates Note When ordering ALWAYS specify Part Model Serial Voltage Phase and Gas Type...

Page 14: ...XPLODED VIEWS Item Part No Description 11 G1081X Splash Guard S S XX 4 Optional G1082X Splash Guard S S XX 6 Optional G1083X Splash Guard S S XX 8 Optional G1084X Splash Guard S S XX 10 Optional G1237...

Page 15: ...XX CH CHARBROILER OPERATION MANUAL 13 PARTS LISTS AND EXPLODED VIEWS EXPLODED VIEW CH 6 8 10 12 14 Note When ordering ALWAYS specify Part Model Serial Voltage Phase and Gas Type...

Page 16: ...3 CH 16 44 T3124X Grease Pan set 3 CH 18 45 T3125X Grease Pan set 4 CH 20 46 T3126X Grease Pan set 4 CH 22 47 T3078V S S Heat Shield w Handle CH 4 48 T3079V S S Heat Shield w Handle CH 6 49 T3080V S S...

Page 17: ...ants Stones and Valves are covered for a period of SIX MONTHS All Ceramic Baking Decks are covered for a period of THREE MONTHS The installation of these replacement decks is the responsibility of the...

Page 18: ...offering a wealth of refrigeration and cooking expertise Products include walk in coolers and freezers hot and cold display cabinets cases and storage systems commercial ovens rotisseries and cooking...

Reviews: