Applicable
Supply
Burner
to model
Pressure
Pressure
being tested
(mbar)
(mbar)
Net 1
Net 2
Gross 1 Gross 2
main 1 main 2
I
2H
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
I
2E+
X
G20/25
20/25
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
I
2H
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
I
2H
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
I
2E+
X
G20/25
20/25
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
I
2ELL
X
G25
20
8.7
5.3
10.55
5.9
11.7
2.15
3.5
1.50
3.1
6.3
I
2E
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
2
H
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
X
G25.1
25
8.7
5.3
10.55
5.9
11.7
2.15
3.5
1.50
3.1
6.3
I
2H
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
I
2H
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
Lithuania (LT)
I
2H
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
I
2L
X
G25
25
8.7
5.3
10.55
5.9
11.7
2.15
3.5
1.50
3.1
6.3
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
I
2E
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
I
2H
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
Slovenia (SL)
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
I
2H
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
I
2H
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
I
2H
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
I
2H
X
G20
20
8.7
5.3
10.55
5.9
11.7
2.05
3.1
1.35
6.3
6.3
* ONLY FOR CERTAIN TYPES OF NON-DOMESTIC APPLIANCES
(1) if convertible in field must supply additional instructions
G20
NATURAL GAS
# THE COUNTRY HAS THE GAS BUT THEY DO NOT MARKET THE GAS AS A CATEGORY
G30
BUTANE GAS
EN Standards require the orifice size to be displayed on spud body and air shutters sealed in position.
G31
PROPANE GAS
(FR) - I3B, I3P--50mbar supply for catering appliances
G30/31
BUTANE / PROPANE
(IT) - I2M-- LPG/Air mixture 42.29 MJ/m3
G20/25
Natural gas / Low heating value natural gas
+ indicates unregulated appliance or regulator is put out of action and sealed at the factory.
Burners - Main 1, Net/Gross 1= single burner venturi. Main 2, Net/Gross 2= Dual burner venturi
Luxembourg(LU)
Latvia (LV)
COUNTRY (code)
Germany (DE)
Hungary (HU)
Italy (IT)
Gas Category
Gas Type
TABLE OF EUROPEAN PRESSURES, GASES AND CATEGORIES (HIGH-HEAT) F, L, C SERIES BROILERS
(Orifice)
Injector size (mm)
main 1 main 2 pilot
Turkey (TR)
Sweden (SE)
Netherlands (NL)
Nominal Input Rate
(kW)
Spain (ES)
United Kingdom (GB)
Switzerland (CH)
Portugal (PT)
Norway (NO)
Belgium (BE)
Poland (PL)
Slovakia (SK)
Austria (AT)
Denmark (DK)
Ireland (IE)
France (FR)
Greece (GR)
Finland (FI)
Air shutter
opening (mm)
Chech Republic (CZ)
Estonia (EE)
I
2H
I
2H
I
2H
I
2S
I
2H
2
E
I
2H
I
2H
I
2H
I
2H
1