PanaFlow Z3 User’s Manual
21
Chapter 3. Programming
3.3.2
Log-in and Primary Pages
To Log-in into the meter perform the following steps:
1.
Press [
] until the lock icon on the meter’s
Measurement View
display is highlighted, then press
[ENTER]
.
2.
In the
Main Menu
Scroll down and select
[Program]
, then press
[ENTER].
3.
Scroll and select desired access level
[Operator]
, then press
[ENTER]
.
4.
Enter the password for Operator access level, and press
[ENTER]
.
5.
After completing the log-in steps you will see the primary pages as shown in the Figure 19. To move from one
page to the next, press [
] or [
] and to scroll to options within a page press [
] and [
].
Note:
For ease of navigation up and down scroll is circular, meaning if you press
[
]
when the first option is
highlighted, then you will be taken to the last option in the page. Similarly, when you press
[
]
when the last
option is highlighted, then you will be taken to the first option in the page.
Figure 19: Log-in Steps and Primary pages
IMPORTANT:
If the keypad has not been pressed for 5 minutes, the XMT1000 exits the Program and returns to
displaying measurements. Because changes can only be retained after the user confirms them, the
meter discards any unconfirmed configuration changes.
3.4
System Settings
Velocity
0.000
m/s
Main Menu
Errors/Warnings
Flow Info
Display Format
Program
Admin
Factory
9
9
WARNING!
After Entering the correct
Password, the system will go
to config mode. Confirm it,
Press Enter!
9
Enter Operator Password
111111
[ ]
9
Program
2
9
[ ]
ESC
MOVE
[ ]
[ ]
ENTER
MODF
System
View Error Log
Meter Settings
Meter Units
Input/Output
Digital Output (Std)
Analog Output (Std)
Communication Port
Option Comm (Slot 1)
Channel 1
Channel 2
Channel 3
Composite
Programming
Calibration Mode
Calibration Type
Reset K-Table
Meter Factor
Calibration
Reset K-Table
K-Table Selection
No. of Points
K-Table
Calibration
Digital Output (Std)
Option Comm (Slot 1)
Input/Output
Log-in Steps
PRIMARY PAGES
9
Operator
Flow Info
Keypod Lockout
Errors/Warnings
Main Menu
Software Upgrade
Reset Error Log
Analog Output (Std)
Option I/O (Slot 2)
Operator Access or Higher
Summary of Contents for Panametrics PanaFlow Z3
Page 1: ...Flow 910 311 Rev C April 2019 Panametrics com PanaFlow Z3 User s Manual...
Page 2: ......
Page 4: ...ii no content intended for this page...
Page 8: ...Contents vi PanaFlow Z3 User s Manual...
Page 12: ...Preface x PanaFlow Z3 User s Manual no content intended for this page...
Page 21: ...PanaFlow Z3 User s Manual 9 Chapter 2 Installation Figure 8 Lifting the PanaFlow Z3 System...
Page 25: ...PanaFlow Z3 User s Manual 13 Chapter 2 Installation Figure 12 Remote Mount Wiring Diagram...
Page 26: ...Chapter 2 Installation 14 PanaFlow Z3 User s Manual no content intended for this page...
Page 58: ...Chapter 3 Programming 46 PanaFlow Z3 User s Manual no content intended for this page...
Page 86: ...Appendix A Specifications and Model Configurations 74 PanaFlow Z3 User s Manual...
Page 104: ...Appendix B Data Records 92 PanaFlow Z3 User s Manual no content intended for this page...
Page 108: ...Appendix D CE Mark Compliance 96 PanaFlow Z3 User s Manual no content intended for this page...
Page 110: ...Warranty 98 PanaFlow Z3 User s Manual no content intended for this page...