Flexflo 887 Series Surge Reliever Manual  |  1

Copyright 2020 Baker Hughes Company. All rights reserved.

Scope

This manual provides instructions for installing, operating, 

maitianing  and  determining  the  Jacket  Pressure  Set  Point 

(JPSP) for all sizes of Flexflo surge relievers.

Product Description

The Flexflo Surge Reliever consists of a slotted metal Core over 

which  a  flexible  rubber  tube  is  installed.  Tubes  each  have  a 

maximum allowable differential pressure rating, based on ASME 

Class ratings, and they are molded in a number of different rubber 

compounds to meet different applications. The Core has two sets 

of openings or slots arranged around the outer circumference of 

the Core. The inlet slots are separated from the outlet slots by a 

metal barrier. The volume enclosed by the Body sleeve and the 

outside surface of the Liner is a pressure chamber known as the 

Jacket space. A ported metal Liner is located around the Tube 

and prevents over expansion of the Tube. The volume between 

the  tube  and  the  Liner  is  known  as  the Annular  volume.  The 

Jacket and the Annular volume are connected by the ports in the 

Liner, and together make up the Total Volume, which is charged 

with compressed, dry gas (not with liquid).

Principles of Operation 

(Refer to Figure 1 to identify parts).

When  the  inlet  pipeline  pressure  (upstream  of  the  Surge 

Reliever) plus the added pressure required to over come 

the  Tube  material’s  natural  resistance  to  expand  (the  Tube’s 

Minimum Differential pressure or DF Minimum) exceeds the 

Jacket  Pressure  Set  Point  of  the  Flexflo  Surge  Reliever,  the 

Flexflo will start to open and start to relieve the line pressure 

upstream of the Flexflo Surge Reliever.

Table Of Contents

Product Description ..................................................................................................................1
Surge Reliever Markings...........................................................................................................1
Principles of Operation .............................................................................................................1
Installation ..................................................................................................................................2
Set Jacket Pressure Set Point ..................................................................................................4
Tube Differential Pressure ........................................................................................................5
Field Assembly and Disassembly ............................................................................................6
Product Support ........................................................................................................................10
Field Disassembly and Reassembly Tables ............................................................................11

Flow

Liner

Tube

Annular 

Volume

Jacket Volume

Short Length 

is Down-

stream End

Body Sleeve

Jacket at Loading Port

Surge Reliever Markings

Figure 1 - Partial Cutaway of Flexflo Surge Reliever

When the pressure at the inlet of the exceeds the Jacket 

Pressure  Set  Point  pressure  by  the  Tube’s  DF  Minimum 

pressure, the valve will start to open. Fluid at the inlet will be 

directed  up  through  the  upstream  slots  in  the  Core,  between 

the  inner  surface  of  the Tube  and  around  the  outside  surface 

of the Core’s Barrier, down into the downstream slots into the 

downstream surge line. Minor surges may be absorbed by just 

the action of the Tube expanding slightly relieving line pressure 

without releasing fluid from the upstream pipeline. Reaction time 

for the Surge Reliever is very rapid, in the range of milliseconds. 

The additional volume of compressible gas in the Jacket space 

allows rapid expansion of the Tube.

Note: Temperature variations will cause the Jacket pressure 

to vary. See temperature changes Page 2.

Summary of Contents for Flexflo 887

Page 1: ...Flexflo Model 887 Surge Reliever Instruction Manual Rev C Baker Hughes Data Classification Public ...

Page 2: ...TICULAR RE QUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CON NECTION WITH INSTALLATION OPERATION OR MAINTENANCE SHOULD FURTHER INFOR MATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COV ERED SUFFICIENTLY FOR THE CUSTOMER OPERATOR ...

Page 3: ...red to over come the Tube material s natural resistance to expand the Tube s Minimum Differential pressure or DF Minimum exceeds the Jacket Pressure Set Point of the Flexflo Surge Reliever the Flexflo will start to open and start to relieve the line pressure upstream of the Flexflo Surge Reliever Table Of Contents Product Description 1 Surge Reliever Markings 1 Principles of Operation 1 Installati...

Page 4: ...sure or add pressure as needed to the jacket however it also will change pressure over time so adjustments will be needed See instruction W 887 15LH B00 1 if this method is chosen Adjusting pressure with a bottle assembly Installation 1 Bottles assemblies are coated to allow them to be buried in the ground with only the top of the bottle s exposed The purpose of embedding the bottles in the ground...

Page 5: ...d for higher than the maximum pressures required at both the Inlet and the Jacket Loading ports of the Flexflo Surge Reliever 1 Increase the pressure in the Jacket Loading port to a pressure slightly approximately 50 psig or 3 45 barg above the desired Relief Set Point pressure the Line pressure where the Flexflo Surge Reliever will start to open and relieve the upstream pipeline pressure If neces...

Page 6: ...t Port connection 7 Determine the pressure the 887 Surge Reliever will be fully open Add DF Max to the Jacket Pressure Set Point pressure 41 psid 877 psig 918 psig 2 8 bard 60 4 barg 63 2 barg This is the approximate pipeline pressure where the 887 surge reliever will be fully open 918 psig 8 Verify the Jacket Pressure Set Point pressure will remain constant enough for the application B Direct flo...

Page 7: ... 23 1 58 23 1 58 39 2 69 12 300 NBR 846 75 600 10 0 69 24 1 65 23 1 58 41 2 83 4 100 HNBR 740 85 600 30 2 07 66 4 55 39 2 69 86 5 93 6 150 HNBR 740 85 600 24 1 65 65 4 48 31 2 13 83 5 72 8 200 HNBR 740 85 600 15 1 03 31 2 13 20 1 38 40 2 76 10 250 HNBR 740 85 600 15 1 03 30 2 07 20 1 38 39 2 69 12 300 HNBR 740 85 600 14 0 96 30 2 07 19 1 31 39 2 69 4 100 HNBR 744 75 300 20 1 4 51 3 52 35 2 41 66 4...

Page 8: ...ure 6 Turn all tie stud nuts counter clockwise 3 Turn each jacking nut so that the face of the washer is flush with the face of the line flange as shown in Figure 7 below Figure 7 Jacking nuts flush with line flange face 4 Rotating each jacking nut turn at a time spread the line flanges apart so that each flange is tight against the remaining tie nut washers as shown in Figure 8 below Figure 8 Spr...

Page 9: ... in Figure 12 below Figure 12 Remove the outlet cover plate 9 Remove the outlet body sleeve O ring as shown in Figure 13 below Depending on the assembly the O ring may come out with the cover plate or may remain inside the Surge Reliever body Figure 13 Remove outlet body sleeve O ring 10 Remove the body sleeve and inlet body sleeve O ring as shown in Figure 14 below Depending on the assembly the O...

Page 10: ...emove tube from core and replace Note A hydraulic press is recommended for removal and installation of the tube If a press is not available it may be preferable to cut the old tube off of the core rather than attempt to remove it intact 13 Replace the tube and core into the liner as shown in Figure 17 below Figure 17 Replace tube and core in liner 14 Replace the body sleeve O rings body sleeve out...

Page 11: ...ver is installed horizontally and replace the cover plate O rings as shown in Figure 20 below O rings should be evenly covered with a light coat of O ring lubricant prior to installation Figure 20 Re install cover plate O rings 17 Replace the body assembly in the line as shown in Figure 21 below Use caution to avoid O ring damage as the body assembly slides between the line flanges Figure 21 Repla...

Page 12: ...he appropriate torque value as shown in Figure 24 below Nuts should be tightened in a criss cross or star pattern in a three step process to avoid unbalanced torquing Recommended torque patterns and intermediate and final torque values are found in Table 4 at the end of this procedure Figure 24 Tighten tie nuts to appropriate torque value 21 Replace the jacket loading connections and other fitting...

Page 13: ... x8 x8 300 10 x8 x10 300 12 x8 x12 300 6 x6 x6 600 8 x6 x8 600 10 x6 x10 600 Table 1 Jacking Nut and Stud Removal Layout NOTE Positions of Jacking Nuts are indicated by hex nut locations Studs for removal are indicated by shaded circles 12 x12 x12 150 14 x12 x14 150 16 x12 x16 150 6 x6 x6 300 8 x6 x8 300 10 x6 x10 300 Table 1 Jacking Nut and Stud Removal Layout NOTE Positions of Jacking Nuts are i...

Page 14: ...e Class Component Weight Complete Re liever Body Assembly Cover Plate Body Sleeve Tube Core1 Core lbs kg lbs kg lbs kg lbs kg lbs kg lbs kg 12 150 2875 1304 1627 738 145 66 602 273 436 198 418 190 300 4081 1851 1784 809 167 76 606 275 453 206 423 192 600 6436 2919 2485 1127 174 79 937 425 592 269 562 255 10 150 1871 849 912 414 100 45 297 135 220 100 210 95 300 2883 1308 1189 539 121 55 409 185 23...

Page 15: ...Flexflo 887 Series Surge Reliever Manual 13 Copyright 2020 Baker Hughes Company All rights reserved Notes ...

Page 16: ...rent information The Baker Hughes logo Flexflo and Mooney are trademarks of Baker Hughes Company Other company names and product names used in this document are the registered trademarks or trademarks of their respective owners BHMY Flexflow 887 IOM 31683C 0920 09 2020 Direct Sales Office Locations Find the nearest local Channel Partner in your area valves bakerhughes com contact us valves bakerhu...

Reviews: