 bajaj electricals limited                                                                                 Page 3 of 5 

 

Technical Specification table

 

Dimensions (in mm) (Ref. 

fig.2)

 

Model

 

Capacity 

(in Litres)

 

Element 

Rating 

(in Kw)

 

Features

 

A

 

B

 

C

 

D

 

E

 

F

 

Colours

 

Bajaj Majesty

 

1.0

 

3.0

 

Safety 

Valve, 

Thermostat 

Thermal 

cut-out 

Fusible 

plug, Neon 

Lamps.

 

162

 

336

 

65

 

144

 

80

 

224

 

Ivory 

and 

Grey

 

Bajaj Majesty

 

1.0

 

4.5

 

Safety 

Valve, 

Thermostat 

Thermal 

cut-out 

Fusible 

Plug, Neon 

Lamps. 

 

162

 

336

 

65

 

144

 

80

 

224

 

Ivory 

and 

Grey

 

Bajaj Majesty

 

3.0

 

3.0

 

Safety 

Valve, 

Thermostat 

Thermal 

cut-out 

Fusible 

plug, Neon 

Lamps.

 

202

 

370

 

54

 

192

 

100

 

180

 

Ivory 

and 

Grey

 

Bajaj Majesty

 

3.0

 

4.5

 

Safety 

Valve, 

Thermostat 

Thermal 

cut-out 

Fusible 

plug, Neon 

Lamps

 

202

 

370

 

54

 

192

 

100

 

180

 

Ivory 

and 

Grey

 

Due to continuous efforts for improvement, specifications are subject to changes.

 

 

Mounting And Installation of Bajaj 

Instant Water Heater (Fig. 2) 

1. 

Mount the Majesty Instant Water Heater (IWH) at a 

suitable place on the wall. Ensure that it's in a 

perfectly vertical position.

 

2. 

A set of screws and Template for marking holes on 

the wall are provided with this unit to enable you 

mount the unit suitably on the wall.

 

3. 

Provide electric power supply connection to the 

unit.

 

4. 

Please ensure that D.P. switch unit of 30 amp rating 

is used.

 

5. 

Connect the inlet of the unit to the incoming water 

supply line.

 

6. 

In case of multi point usage get a licensed plumber, 

electrician to connect the outlet of the heater to the 

various points of usage.

 

7. 

The cold and hot water pipes should not be 

connected directly to the inlet and outlet of the heater. They should instead be connected by flexible tubes of 

appropriate material. In case of direct pipe connections, tightening of couplings using wrench can damage 

the heater unit.

 

8. 

The overall & mounting dimensions are shown in Fig.2.

 

 