BAISHEN TECHNOLOGY CLJ-03A03 Operating Manual Download Page 3

 

2

Option accessory: Sampling bracket 

Printer. 

3. Usage attention   

3.1 The apparatus can not be using in active gas, rot gas environment, otherwise it 

maybe bring blast danger and damage apparatus.  

3.2 When using charger , pay attention to local voltage to prevent  damage charger.  

3.3 when using, the apparatus can not be grave impacted, otherwise, it will make 

optical system damage and  shell disrepair which affect usage.  

3.4 The Apparatus is a laser product, if it has any trouble, please contact with 

manufacturer, it can not be disassembled by oneself.  

4. Panel display control button introduction  

 Company registered mark  

 Liquid crystal display monitor 

 Test , run and stop button (RUN) 

 Menu selection key 

⑸、⑹

 Set up key 

 Mains switch 

 RS232/RS485 and print port 

 Charge port 

 Tripod fixing screw hole 

 Humiture test outlet 

 Sampling outlet 

  

Key position 

State 

Run 

Menu 

π

 

θ

 

Initial interface 

Run 

Menu 

209E/ISO Reset Chinese English Shift

 

Menu 

Exit 

Select 

Up 

Down 

Run 

Stop 

Menu 

N/A 

209E/ISO Mode  

Data reading 

Exit 

Data printing 

Up 

Down 

5. Displaying interface and panel function set up  

Summary of Contents for CLJ-03A03

Page 1: ...9 2005 OPERATING MANUAL ISO9001 2000 CERTIFIED SUZHOU CLEANING TECH RESEARCH INSTITUTE BAISHEN TECHNOLOGY SUZHOU CO LTD Attention Before operating CLJ 03A03 type temperature and humidity Laser Particle Counter user must read this operating manual carefully please Keeping the manual for reference ...

Page 2: ...mperature and humidity with which we can test T RH 2 Open the box acceptance check 2 1 This is an accurate test instrument the product has already proceeded detection before leaving the factory the consumers can directly be used for particle s testing and inspecting when receiving goods the customers should check the transportation damage situation first if no wrapping transportation damage situat...

Page 3: ...s is a laser product if it has any trouble please contact with manufacturer it can not be disassembled by oneself 4 Panel display control button introduction Company registered mark Liquid crystal display monitor Test run and stop button RUN Menu selection key Set up key Mains switch RS232 RS485 and print port Charge port Tripod fixing screw hole Humiture test outlet Sampling outlet Key position S...

Page 4: ...00 00 Press menu key cursor is real line press Key to ascertain year after setting up year press menu key again cursor is broken line Set up month day hour minute according to up mentioned operation Set up month move cursor to 00 00 00 00 00 Set up day move cursor to 00 00 00 00 00 Set up hour move cursor to 00 00 00 00 00 Set up minute move cursor to 00 00 00 00 00 周期 CLJ03A03 Particle Counter Ba...

Page 5: ... move cursor to point back then press menu key cursor is real line press key again choice need the point press menu key again end setting up point C 3 Fix each dot times Press key move cursor to times back then press menu key cursor is real line press key again choice needed times press menu key end time setting up 周期 周期 Print yes 209E yes Point 2 Times 2 Clock 02 05 09 11 10 Duration 1 Read Curso...

Page 6: ...y move cursor to the back of cycle then press menu key cursor is real line press key again choice the check and measure cycle Unit minute press menu key after setting end cycle setting F read 周期 周期 Print yes 209E yes Point 2 Times 2 Clock 02 05 09 11 10 Duration 1 Read Cursor Print yes 209E yes Point 2 Times 2 Clock 02 05 09 11 10 Duration 1 Read Print yes 209E yes Point 2 Times 2 Clock 02 05 09 1...

Page 7: ... test meanwhile pump start up after a minute it stop the screen will display each particle consistence per minute Add up Apparatus reset after finishing operation proceed apparatus reset please connect filter to samplinging outlet filter arrow direction points to apparatus sampling outlet and come into running state till 0 5μ m display for 0 At Test spot enter to test point and name Press run key ...

Page 8: ... repeatedly recover starting condition As the check number and time arrive setting value the meter can calculate UCL automatically Cleanliness Comparison ISO14644 1 FS 209E PCS CF 0 5 5 0 5 100 100 6 1000 1000 7 7 10000 10000 70 8 100000 100000 700 9 100000 100000 700 UCL mean value 95 certainty factors PCS CF If the meter is connected to printer meanwhile it has already set up print mode the scre...

Page 9: ...2 Read storager content open CLJ03A03 power supply start computer and run CLJ03A EXE Choice Online operation Read storager content if connecting is right the user can read the past store data from CLJ03A03 CLJ03A03 will be showed Computer link Uploading data Transfer completed will be not showed on the liquid crystal screen till the schedule bar of host computer is completed 6 3 print hook in smal...

Page 10: ...unter OPERATING MANUAL SUZHOU CLEANING TECH RESEARCH INSTITUTE BAISHEN TECHNOLOGY SUZHOU CO LTD Add 31 Qihong Road Tongyuan Road SIP Suzhou Zip 215006 Phone 86 512 62522538 Fax 86 512 62522938 http www baishen com E mail clean baishen com 2004 Printed in Suzhou ...

Reviews: