TradiePack - User Guide v1.3
Installation & User Guide
TP Range
19
Figure 15: Voltage Curve Lead Acid vs Lithium
The TradiePack battery voltages below are a useful guide:
1.
A normal full battery open circuit voltage (Voc) with no load rests at 13.3V to 13.8V;
2.
Depending on the load, voltage may dip 0.5V below the Voc;
3.
Below 13V Voc the battery is low and should be charged to promote a long lifespan.
4.
Below 12V Voc the battery is close to empty, and should be charged straight away;
5.
Low Voltage Disconnect (LVD) is set at ~10.5V.
Smart Shunt
All TradiePacks have a built in Shunt, providing access to all load and charging data in and out of the
TradiePack.
The BTLITH-TP110 and BTLITH-TP110-24 feature a Victron SmartShunt. To view all battery
information, download the “Victron Connect” app from the App Store or Google Play and connect to
the device via Bluetooth from your smart device.
The default PIN code is “000000” (six zero
s) (
The BTLITH-TP220 features a Victron SmartBMV. Some basic information is available on the BMV
display. (
) Cycle through the displayed information by using the
+/-
buttons on the device.
More detailed information is available using the “Victron Connect” app. Download the
“Victron
Connect” app from
the App Store or Google Play and connect to the device via Bluetooth from your
smart device.
The default PIN code is “000000” (six zeros)
0
2
4
6
8
10
12
14
16
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Batt
ery
Vo
ltag
e
(V
)
Depth of Discharge (DoD)
Discharge Curve: Lithium vs Lead Acid
Lead Acid Voltage (v)