background image

IMDSM05 DIGITAL I/O SLAVE MODULE CONFIGURATION

INTRODUCTION

I-E96-411A   

A - 3

Table A-5.  Switch S5 Settings

Switch

Position

Function

1

2

1

0

Enable contacts 1 - 4 of the address switch.

Disables contacts 1 - 4 of the address switch.

1

0

Enable contacts 5 - 8 of the address switch.

Disables contacts 5 - 8 of the address switch.

NOTE: 0 = closed or ON, 1 = open or OFF.

Table A-6.  Jumpers J1 through J16 Settings

Jumper Position

Function

1-2

Normal input or output.

2-3

Two wire isolated output.

Table A-7.  Jumper J17 and J18 Settings

Jumper

Jumper

Position

Function

J17

1-2

DSM module communicating to an NLMM01 mod-
ule.

J18

J17

2-3

DSM module communicating to an IMLMM02, 
MFC, or MFP module.

J18

Summary of Contents for Infi 90 NIDO01

Page 1: ...Process Control and Automation Solutions from Elsag Bailey Group E96 411 Digital Output Termination Module NIDO01...

Page 2: ...UIPEMENTS LECTRONIQUES SONT SENSIBLES AUX PERTURBATIONS PAR FR QUENCE RADIO DES PR CAUTIONS DEVRONT TRE PRISES LORS DE L UTILISATION DU MAT RIEL DE COMMUNICATION PORTATIF LA PRUDENCE EXIGE QUE LES PR...

Page 3: ...s modules The NIDO01 Digital Output Termination Module terminates digital field wir ing to IMLMM02 Logic Master Module IMDSM05 Digital I O Slave Module This product instruction explains how to install...

Page 4: ...ugh 2 7 Original 3 1 Original 4 1 through 4 2 Original 5 1 Original A 1 through A 3 Original B 1 through B 2 Original Index 1 Original NOTE On an updated page the changed text or table is indicated by...

Page 5: ...r of the cabinet containing these externally powered circuits must be marked with a warning stating that multiple power sources exist p 2 6 SPECIFIC CAUTIONS Remove modules slave master or termination...

Page 6: ...ation Le cas echeant un avertissement signalant la presence de sources d alimentation multiples doit entre appose sur la porte de l armoire p 2 6 ATTENTIONS D ORDRE SP CIFIQUE Retirer les modules asse...

Page 7: ...able Connections 2 3 Cable Installation 2 4 NKTU02 NKTU12 and NKTM01 Cables 2 5 Installing the Termination Module 2 5 Terminal Wiring 2 6 SECTION 3 MAINTENANCE 3 1 INTRODUCTION 3 1 MAINTENANCE SCHEDUL...

Page 8: ...1 1 Nomenclature 1 2 1 2 Glossary of Terms and Abbreviations 1 3 1 3 Specifications 1 3 1 4 Reference Documents 1 4 2 1 NIDO01 Cable Applications 2 4 3 1 Maintenance Schedule 3 1 5 1 Spare Parts List...

Page 9: ...rs and technicians should read this manual before installing and placing the NIDO01 termination module into operation Do not put the IDO termination module into operation until this instruction is rea...

Page 10: ...Bailey Controls Com pany Appendices A and B These appendices list the quick reference information neces sary to configure the IMDSM05 and IMLMM02 modules HOW TO USE THIS MANUAL Read this manual throug...

Page 11: ...t provides electrical and communication sup port for INFI 90 Network 90 modules Termination Module Provides input output connection between plant equipment and INFI 90 Network 90 modules TMU Terminati...

Page 12: ...RENCE DOCUMENTS 1 4 I E96 411A REFERENCE DOCUMENTS Table 1 4 is a list of related hardware Table 1 4 Reference Documents Number Document I E96 209 IMLMM02 Logic Master Module I E96 309 IMDSM05 Digital...

Page 13: ...discharge may damage CMOS devices on modules in the cabinet Use grounded equipment and static safe practices when working with modules 1 Use Static Shielding Bag Keep the modules in the static shield...

Page 14: ...allation A 6 amp 250 volt fuse Bailey part number 194776A16001 should be installed in fuse clip F1 of every IDO module Remove the front cover and verify the fuse is installed If the fuse is not instal...

Page 15: ...lave module Figure 2 3 shows the cables to use and the cable con nections for two different NIDO01 module applications Table 2 1 lists each cable and its application Figure 2 1 NIDO01 Termination Modu...

Page 16: ...e module 61 200 NKTM01 ribbon com munication cable Connects the IDO module to the master or slave module P1 of the IDO module to P3 of the master or slave module 30 100 Standard 14 to 22 AWG wire Conn...

Page 17: ...ng from the J2 end of the NKTU02 or NKTU12 cable to the shield bus bar 5 Insert the J1 end use the remaining end of the NKTM01 cable of the NKTU01 or NKTU12 cable into the termination mounting unit ba...

Page 18: ...resentent un risque de choc electrique meme lorsque l alimentation du systeme est debranchee du panneau d entree l alimentation Le cas echeant un avertisse ment signalant la presence de sources d alim...

Page 19: ...of the ter mination mounting unit to the common terminal of the IDO module 5 Insert the IDO module until it locks securely into place 6 Replace snap on the front cover The NIDO01 module is ready for...

Page 20: ...e MAINTENANCE SCHEDULE Execute the tasks in Table 3 1 at the specified intervals Table 3 1 Maintenance Schedule Task Interval Clean and tighten all power and field wiring connections Every 6 months or...

Page 21: ...If not already installed insert the appropriate fuse into fuse clip F1 6 Cut the jumpers on the replacement IDO module to match the jumper settings of the defective IDO module 7 Connect all wiring re...

Page 22: ...e 5 Install the replacement fuse into fuse clip F1 6 Insert the IDO module until it locks securely into place 7 Install snap on the front cover of the IDO module 8 Apply power to the cabinet containin...

Page 23: ...applicable 3 Bailey instruction manual number page number and refer ence figure that identifies the part Order parts without commercial descriptions from the nearest Bailey Controls Company sales offi...

Page 24: ...able address switch dipswitch S5 digital input Figure A 1 Digital I O Module ENABLE SWITCH ADDRESS SELECTION SWITCH MODULE CONFIGURATION SWITCH S3 S5 S1 S4 S2 I O JUMPERS J1 J16 CONTROL MODULE SELECTI...

Page 25: ...I O points to outputs Set group A I O points to inputs 1 0 Set group B I O points to outputs Set group B I O points to inputs 1 0 Module is an interface between a master module and a digital logic st...

Page 26: ...contacts 5 8 of the address switch Disables contacts 5 8 of the address switch NOTE 0 closed or ON 1 open or OFF Table A 6 Jumpers J1 through J16 Settings Jumper Position Function 1 2 Normal input or...

Page 27: ...odule Configuration consists of setting the module address dipswitch S2 and digital input type jumpers J1 through J8 Refer to the IMLMM02 Logic Master Module instruction manual for detailed instructio...

Page 28: ...S2 Settings Module Address Address Example Switch Position Binary Value 4 16 5 8 6 4 7 2 8 1 0 0 0 0 0 0 8 0 1 0 0 0 16 1 0 0 0 0 24 1 1 0 0 0 31 1 1 1 1 1 NOTE 0 closed or ON 1 open or OFF Table B 3...

Page 29: ...2 I IMDSM05 configuration B 1 IMLMM02 configuration B 1 Installation 2 2 Instruction content 1 2 Intended user 1 1 J Jumpers 2 2 M Maintenance schedule 3 1 Module replacement procedures 4 1 O Overview...

Page 30: ...8756 ASIA PACIFIC 152 Beach Road Gateway East 20 04 Singapore 189721 Telephone 65 391 0800 Telefax 65 292 9011 EUROPE AFRICA MIDDLE EAST Via Puccini 2 16154 Genoa Italy Telephone 39 10 6582 943 Telefa...

Reviews: