WARNING notices as used in this instruction apply to hazards or unsafe practices that could result in
personal injury or death.

CAUTION notices apply to hazards or unsafe practices that could result in property damage.

NOTES highlight procedures and contain information that assists the operator in understanding the
information contained in this instruction.

WARNING

INSTRUCTION MANUALS

DO NOT INSTALL, MAINTAIN, OR OPERATE THIS EQUIPMENT WITHOUT READING, UNDERSTANDING,
AND FOLLOWING THE PROPER Elsag Bailey INSTRUCTIONS AND MANUALS; OTHERWISE, INJURY OR
DAMAGE MAY RESULT.

RADIO FREQUENCY INTERFERENCE

MOST ELECTRONIC EQUIPMENT IS INFLUENCED BY RADIO FREQUENCY INTERFERENCE (RFI). CAU-
TION SHOULD BE EXERCISED WITH REGARD TO THE USE OF PORTABLE COMMUNICATIONS EQUIP-
MENT IN THE AREA AROUND SUCH EQUIPMENT. PRUDENT PRACTICE DICTATES THAT SIGNS
SHOULD BE POSTED IN THE VICINITY OF THE EQUIPMENT CAUTIONING AGAINST THE USE OF POR-
TABLE COMMUNICATIONS EQUIPMENT.

POSSIBLE PROCESS UPSETS

MAINTENANCE MUST BE PERFORMED ONLY BY QUALIFIED PERSONNEL AND ONLY AFTER SECURING
EQUIPMENT CONTROLLED BY THIS PRODUCT. ADJUSTING OR REMOVING THIS PRODUCT WHILE IT IS
IN THE SYSTEM MAY UPSET THE PROCESS BEING CONTROLLED. SOME PROCESS UPSETS MAY
CAUSE INJURY OR DAMAGE.

AVERTISSEMENT

MANUELS D’OPÉRATION

NE PAS METTRE EN PLACE, RÉPARER OU FAIRE FONCTIONNER L’ÉQUIPEMENT SANS AVOIR LU,
COMPRIS ET SUIVI LES INSTRUCTIONS RÉGLEMENTAIRES DE Elsag Bailey. TOUTE NÉGLIGENCE À
CET ÉGARD POURRAIT ÊTRE UNE CAUSE D’ACCIDENT OU DE DÉFAILLANCE DU MATÉRIEL.

PERTURBATIONS PAR FRÉQUENCE RADIO

LA PLUPART DES ÉQUIPEMENTS ÉLECTRONIQUES SONT SENSIBLES AUX PERTURBATIONS PAR
FRÉQUENCE RADIO. DES PRÉCAUTIONS DEVRONT ÊTRE PRISES LORS DE L’UTILISATION DU MATÉ-
RIEL DE COMMUNICATION PORTATIF. LA PRUDENCE EXIGE QUE LES PRÉCAUTIONS À PRENDRE
DANS CE CAS SOIENT SIGNALÉES AUX ENDROITS VOULUS DANS VOTRE USINE.

PERTURBATIONS DU PROCÉDÉ

L’ENTRETIEN DOIT ÊTRE ASSURÉ PAR UNE PERSONNE QUALIFIÉE EN CONSIDÉRANT L’ASPECT
SÉCURITAIRE DES ÉQUIPEMENTS CONTRÔLÉS PAR CE PRODUIT. L’AJUSTEMENT ET/OU L’EXTRAC-
TION DE CE PRODUIT PEUT OCCASIONNER DES À-COUPS AU PROCÉDÉ CONTRÔLE LORSQU’IL EST
INSÉRÉ DANS UNE SYSTÈME ACTIF. CES À-COUPS PEUVENT ÉGALEMENT OCCASIONNER DES
BLESSURES OU DES DOMMAGES MATÉREILS.

NOTICE

The information contained in this document is subject to change without notice.

Elsag Bailey, its affiliates, employees, and agents, and the authors and contributors to this publication specif-
ically disclaim all liabilities and warranties, express and implied (including warranties of merchantability and
fitness for a particular purpose), for the accuracy, currency, completeness, and/or reliability of the information
contained herein and/or for the fitness for any particular use and/or for the performance of any material and/
or equipment selected in whole or part with the user of/or in reliance upon information contained herein.
Selection of materials and/or equipment is at the sole risk of the user of this publication.

This document contains proprietary information of Elsag Bailey, Elsag Bailey Process Automation, and
is issued in strict confidence. Its use, or reproduction for use, for the reverse engineering, development
or manufacture of hardware or software described herein is prohibited. No part of this document may be
photocopied or reproduced without the prior written consent of Elsag Bailey.

Summary of Contents for Infi 90 NIAC02

Page 1: ...Process Control and Automation Solutions from Elsag Bailey Group E96 420 Analog Input Calibration Module NIAC02...

Page 2: ...UIPEMENTS LECTRONIQUES SONT SENSIBLES AUX PERTURBATIONS PAR FR QUENCE RADIO DES PR CAUTIONS DEVRONT TRE PRISES LORS DE L UTILISATION DU MAT RIEL DE COMMUNICATION PORTATIF LA PRUDENCE EXIGE QUE LES PR...

Page 3: ...Calibration voltages pass from the IMAMM02 and IMAMM03 Analog Master Modules or an external millivolt cali bration source to the IMASM02 slave module This manual explains how to install and use the N...

Page 4: ...through 4 2 Original 5 1 Original A 1 Original Index 1 Original When an update is received insert the latest changed pages and dispose of the super seded pages NOTE On an update page the changed text...

Page 5: ...alling or removing a cable assigned to that slot Failure to do so could result in damage to the module p 2 3 4 1 It is strongly recommended that all power cabinet I O etc be turned off before doing an...

Page 6: ...n manquement cette proc dure pourrait endom mager le module p 2 3 4 1 Ll est fortement recommande que toutes les alimentations armoire E S etc soient coupees avant d effectuer quelque raccord que ce s...

Page 7: ...CTION 2 1 SPECIAL HANDLING 2 1 UNPACKING AND INSPECTION 2 2 SETUP PHYSICAL INSTALLATION 2 2 Switch Settings 2 2 Cable Installation 2 2 Module Installation 2 4 Terminal Wiring 2 4 SECTION 3 MAINTENANCE...

Page 8: ...4 1 4 Nomenclature 1 5 2 1 NIAC02 Cable Applications 2 3 3 1 Maintenance Schedule 3 1 A 1 Address Switch Settings SW1 A 1 List of Figures No Title Page 1 1 Application Example for the NIAC02 Module 1...

Page 9: ...e module into operation only after reading and understanding this instruction MODULE DESCRIPTION The NIAC02 module is a single printed circuit board that uses one slot in an NTMU01 Termination Module...

Page 10: ...dule to the calibration slot for the IMASM02 module to be calibrated Signal wire terminals are at the front edge of the calibration module for internal or external millivolt source connection Each cal...

Page 11: ...ule Support Services Describes the support services repair parts training docu mentation etc available from Bailey Controls Company Appendix A Describes the IMASM02 Thermocouple Slave Input Module HOW...

Page 12: ...t A card cage that provides housing for INFI 90 Network 90 termination modules Table 1 3 Specifications Property Characteristic Value Power Requirements No power is required by the NIAC02 module Mount...

Page 13: ...Nomenclature Nomenclature Description IMASM02 Thermocouple and Millivolt Input Slave Module NIAM02 Analog Master Termination Module NKTM01 Cable Termination Module Ribbon NKTU02 Cable Termination Mod...

Page 14: ...nd static safe practices when working with modules 1 Use Static Shielding Bag Keep the modules in the static shielding bag until you are ready to install them in the system Save the bag for future use...

Page 15: ...external calibration Switch Settings The calibration select switch selects the source for the calibra tion voltage When set to INT CAL the switch selects the inter nal calibration terminals wired fro...

Page 16: ...VC Jacket NKTM01 cable ribbon Connects NIAC02 module to calibration slot P1 on NIAC02 module to MMU backplane 30 m 100 ft Twisted wire pair Connects NIAC02 module to NIAM02 TB1 terminal 3 and 4 on NIA...

Page 17: ...t of the NIAC02 module 2 Align the NIAC02 module with the guide rails in the TMU card cage and insert the module Terminal Wiring The NIAC02 module connects to the internal or external cali bration sou...

Page 18: ...connection CAUTION If input or output circuits are a shock hazard after disconnect ing system power at the power entry panel then the door of the cabinet containing these externally powered circuits m...

Page 19: ...3 and 4 on the NIAM02 module for internal calibration or to the external millivolt source for external calibration 6 Replace the front cover The NIAC02 module is ready for operation if 1 The circuit b...

Page 20: ...maintenance schedule MAINTENANCE SCHEDULE Execute the tasks in Table 3 1 at the specified intervals Table 3 1 Maintenance Schedule Task Interval Clean and tighten all power and grounding connections E...

Page 21: ...ecommended that all power cabinet I O etc be turned off before doing any termination module wiring Failure to do so could result in equipment damage Do not apply power until all connections are verifi...

Page 22: ...oved 7 Connect and verify all wiring removed in Step 4 8 Verify that wiring and cabling to the calibration module is correct 9 Fully insert the calibration module into the TMU card cage 10 Replace the...

Page 23: ...n part number and quantity 2 Model and serial numbers if applicable 3 Bailey instruction manual number page number and refer ence figure that identifies the part Order parts without commercial descrip...

Page 24: ...as a quick ref erence guide for personnel installing the NIAC02 module Figure A 1 shows the IMASM02 module address select switch SW1 Table A 1 lists the binary addresses for setting SW1 Refer to the...

Page 25: ...t 1 3 Intended user 1 1 M Maintenance schedule 3 1 O Overview 1 1 R References 1 3 Related equipment 1 5 Replacement parts ordering information 5 1 Replacement procedures 4 1 S Setup 2 2 Spare parts 5...

Page 26: ...8756 ASIA PACIFIC 152 Beach Road Gateway East 20 04 Singapore 189721 Telephone 65 391 0800 Telefax 65 292 9011 EUROPE AFRICA MIDDLE EAST Via Puccini 2 16154 Genoa Italy Telephone 39 10 6582 943 Telefa...

Reviews: