10.0 User-Maintenance
Always disconnect power to the machine before performing maintenance. Failure to do this may
result in serious personal injury.
10.1 Changing the Filters
To reduce the risk of injury, disconnect the air filtration system from the power source (unplug)
before servicing or changing filters. Failure to comply may cause serious injury!
There are two filters that need to be changed.
Filter life will vary depending on the amount of usage and the environment of your shop. Clogged filters will reduce the
amount of air circulation.
1. Lift the filter up and pull outward on the bottom edge to remove the filter.
Figure 10-1
2. Remove the
inner filter
by pulling straight out of the cabinet.
3. Remove any protective wrapping from the new filters.
4. Install the filters in reverse of the removal. The outer filter has directional air flow arrows printed on the frame which
depicts the direction of air flow. Make sure it is facing the proper direction when installed. If no directional arrows are
present, the inboard side of the filter will typically have metal support not used on the outboard side.
Replacement Filters:
NOTE:
Baileigh
brand filters are recommended for best performance.
708731 ...... Electrostatic Outer Filter
708732 ...... Washable Electrostatic Outer Filter
708733 ...... Inner Three-Pocket Filter
708734 ...... Charcoal Filter