background image

1

    DISPLAY MANUAL 

DP C18.UART

CONTENT

Content 

1

Introduction 

2

Overview drawing 

3

Specifications 

4

Functional overview 

5

Normal indication area 

6

Button definition 

7

Normal operation 

7

User set 

10

Error code definition 

17

DP C18.UART

CONTENT

Summary of Contents for DP C18.UART

Page 1: ...C18 UART CONTENT Content 1 Introduction 2 Overview drawing 3 Specifications 4 Functional overview 5 Normal indication area 6 Button definition 7 Normal operation 7 User set 10 Error code definition 17...

Page 2: ...play model 1 0 hardware version number B Down row number as below 605P1QB220003 605 Wire length and connector model is 230mm M5 2 P1 design number QB220003 Production date is 21st Nov 2016 SN is 0003...

Page 3: ...3 DISPLAY MANUAL DP C18 UART OVERVIEW DRAWING OVERVIEW DRAWING...

Page 4: ...8V DC Rated current 10mA lines as shown in the figure Maximum operating current 30mA When power off leak current is less than 1uA Operating current supplied to controller 50mA Operation temperature 20...

Page 5: ...utomatically turned on off depending on lighting conditions 5 levels off display backlighting 10 is most dark 100 is highest light 6 Level Support setting power Levels 0 to 5 Trip distance indication...

Page 6: ...level display Display current battery level value 7 Voltage display percentage display Display actual battery level value display mode can be set in the Soc View 8 Speed digital display Display curren...

Page 7: ...utes time can be set in Auto Off the display will be automatically turned off If the password function of the display is activated need to input the correct password to enter into the normal display i...

Page 8: ...Briefly press 0 5s to switch the display between the distance and speed cycle show signal trip distance TRIP total distance ODO maximum speed MAX average speed AVG remaining distance RANGE energy con...

Page 9: ...er can be set in the Brightness If the display is turned on in a dark environment the display backlight headlight will be turned on automatically If the display backlight headlight are turned off manu...

Page 10: ...ocess in the set interface AL Sensitivity Default Mode Unit Brightness Auto Off Power View SOC View TRIP Reset Factory Setting Password Set clock BACK Default Mode Wheel Speed Limit BACK Battery info...

Page 11: ...and enter into Display setting There are thirteen set options in the interface Unit unit switch between the km and mile Briefly press 0 5S or to select Unit and then briefly press 0 5S to enter into...

Page 12: ...press for two times interval time is less than0 5S to exit back to main interface or select BACK EXIT to exit the main menu Power View set output display mode Briefly press 0 5S or to select Power Vie...

Page 13: ...nterval time is less than 0 5S to exit back to main interface or select BACK EXIT to exit back to main interface AL Sensitivity set light sensitivity Briefly press 0 5S or to select AL Sensitivity and...

Page 14: ...ess than 0 5S to exit back to main interface or select BACK EXIT to exit back to main interface Change password After setting the password the interface Password will add option Reset Password Briefly...

Page 15: ...ect Set Clock and then briefly press 0 5S The time is represented in the 24 hour system Cursor stays at the first digit of the clock Briefly press or to select 0 2 and then briefly press 0 5S to confi...

Page 16: ...Max Uncharge Time Current current Last Uncharge Time Last Uncharge Time Res Cap remaining battery capacity Total Cell The number of cell Full Cap Battery capacity of Full charged Cell Voltage 1 Volta...

Page 17: ...nsor inside Have your dealer check the motor stator 10 The motor temperature reaches to the max protection value Stop riding and wait until the LED stop flickering 12 Fault with current sensor inside...

Page 18: ...18 DISPLAY MANUAL DP C18 UART NOTES...

Page 19: ...19 DISPLAY MANUAL DP C18 UART NOTES...

Page 20: ...20 DISPLAY MANUAL DP C18 UART NOTES...

Reviews: