40
Type of motor enclosure
IP X4
Thermal class
F
Motor speed approx. (rpm)
3450
Continuous sound
intensity level dB (A)
≤
70
1)
Max. water temperature (°C)
60
Max. casing interior pressure (bar) 2,5
Characteristics
BADU
®
Resort,
BADU
®
Resort-AK
60 Hz, n = 3450 min
-1
applicable for water
of 20°C
Technical data at 60 Hz BADU Resort 30 / 30-AK 40 / 40-AK 45 / 45-AK 50 / 50 AK 55 / 55 AK 60 / 60-AK 70 / 70-AK 80 / 80-AK 110 / 110-AK
Inlet/outlet d (mm)
75 / 75
90 / 90
90 / 90 110 / 110 110 / 110 110 / 110 110 / 110 110 / 110 110 / 110
Recommended inlet/outlet pipe, PVC pipe, diameter 75 / 75
90 / 90
90 / 90 110 / 110 110 / 110 110 / 110 110 / 110 140 / 140 160 / 140
Power input P1 (kW)
3~ Y/
Δ
400/230 V
1,87
2,62
3,10
3,60
–
3,10
3,60
–
–
Power output P2 (kW)
3~ Y/
Δ
400/230 V
1,50
2,20
2,60
3,00
–
2,60
3,00
–
–
Rated current (A)
3~ Y/
Δ
400/230 V
3,0/5,2
4,3/7,4
5,1/8,8
5,9/10,2
–
5,1/8,8
5,9/10,2
–
–
Power input P1 (kW)
3~ Y/
Δ
690/400 V
–
–
–
–
4,90
–
–
4,90
6,45
Power output P2 (kW)
3~ Y/
Δ
690/400 V
–
–
–
–
4,00
–
–
4,00
5,50
Rated current (A)
3~ Y/
Δ
690/400 V
–
–
–
–
4,4/7,6
–
–
4,4/7,6
5,8/10,0
Weight (kg)
23,0
26,0
28,0
29,0
34,0
28,0
29,0
34,0
41,0
For standard voltage according to IEC 38
and DIN EN 60034 (Euro-voltage).
Suitable for continuous operation at
3~ Y/
Δ
380-420 V / 220-240 V
3~ Y/
Δ
690 V / 400 V
Tolerances ± 5%.
GS-tested pumps according to EN 60335-1.
1)
Measured with a phonometer according to DIN 45635.
KL 95.10.005
Total dynamic head H (m)
Flow rate Q (m
3
/h)
Resort 55
Resort 50
Resort 45
Resort 40
Resort 30
Resort 60
Resort 70
Resort 80
Resort 1
10
60
80
100
150
10
0
32
20
30
40
8
4
12
16
20
50
24
28