![Badger Meter IOG Series Installation And Operation Manual Download Page 15](http://html1.mh-extra.com/html/badger-meter/iog-series/iog-series_installation-and-operation-manual_3596398015.webp)
Register output specifications & wiring
Page 13/20
OG_IOG_BA_02_1401
10. Register output specifications & wiring
10.1 Pulse (model ILR 710)
Register wiring
External DC+: Yellow
External ground: Brown
Pulse output: White
DC Input: 6 to 24 VDC; 10 to 20mA
Outputs: Pulse output with internal pull-up resistor; optional open collector output
with output jumper removal; pulse output is scalable in pulses per liter or pulses per
gallon.
Figure 13: ILR 710 wiring
Yellow
White
Brown
Ground
Pulse
output
Output
jumper
8-24V DC input
ILR 710
Summary of Contents for IOG Series
Page 23: ......