Registers type ILR7XX and ILR7XXT 

 

AC_ILR_BA_02_1632 (October 2019) 

User Manual 

Summary of Contents for ILR 700

Page 1: ...Registers type ILR7XX and ILR7XXT AC_ILR_BA_02_1632 October 2019 User Manual...

Page 2: ...play 6 3 4 Changing the register orientation for all ILR models with display 6 3 5 Changing the display mode for all ILR models with display 7 3 6 Exiting programming mode for all ILR models with disp...

Page 3: ...nt rating All units must be earthed to eliminate risk of electric shock Failure to properly earth a unit may cause damage to that unit or data stored within it Protection class The device has protecti...

Page 4: ...ucts are RoHs compliant Battery disposal The batteries contained in our products need to be disposed of as per your local legislation acc to EU directive 2006 66 EG Failure to adhere to these safety i...

Page 5: ...me of flow through the meter with six digits The batch totalizer totalizes in selected units of measure To reset the batch totalizer after 2 seconds of no flow press and release the RESET button The b...

Page 6: ...drained to 10 of its total capacity and should be changed Normal battery life is five years NOTE A 2 3AA 3 6 VDC battery may also be used as a replacement Low battery indicator 2 6 Checksum To displa...

Page 7: ...ected press the TOTAL button to advance to the scale factor programming 3 2 Scale factor for all ILR models with display The register collects input pulses from the oval gear meter and then determines...

Page 8: ...s gallons quarts or pints Meter Pulse Rate 1 Press the TOTAL button to select a digit selected digits flash Press RESET to change the selected digit The pulse rate can be any value between 00000 01 an...

Page 9: ...de may be either the totalizer screen or the flow rate screen C indicates the totalizer screen and F indicates the flow rate screen The totalizer screen is depicted below Default display 1 While a let...

Page 10: ...illiseconds 40 for 40 milliseconds 100 for 100 milliseconds To advance to the next programming screen hold the TOTAL button Output pulse lenght screen About Output Pulse Length The pulse rate duration...

Page 11: ...allon if the selected unit of measure is gallons quarts or pints To advance to the next programming screen hold the TOTAL button NOTE Error checking will not allow the user to advance to the next scre...

Page 12: ...750T Indicated by 1 9 on the left hand side of the display followed by a hyphen this screen allows the setting of the linearization in total 9 points Linearization point 1 of 9 Press the TOTAL button...

Page 13: ...0 15 needs to be set as correction NOTE Minimum 3 linearization points needs to be programmed The flow rates do not have to be programmed from low to high the software will sort the flow rates automa...

Page 14: ...witch outputs Green and white Ratings Max power 10W not to exceed max voltage 200 VDC peak AC max current 0 5A DC peak AC Outputs Raw reed switch output with no signal conditioning ILR 740 wiring Puls...

Page 15: ...0 ohms flow rate is linear scaled between 4mA minimum and 20mA maximum set points Pulse output with internal pull up resistor 1 K optional open collector output when the jumper is removed Please open...

Page 16: ...ess declaration Page 14 AC_ILR_BA_02_1632 October 2019 6 RETURN OF GOODS FOR REPAIR HARMLESSNESS DECLARATION Please refer to our claims return form harmlessness declaration under https www badgermeter...