6. TECHNICAL SPECIFICATIONS
Display
Type
High intensity transflective numeric and alphanumeric LCD, with white LED backlight
Dimensions
2.13” x 1.14” (54 x 29 mm)
Digits
Seven 0.47” (12 mm) and seven 0.28” (7 mm) digits
Refresh rate
During operation 8 times/sec, it will automatically switch to 1 time/sec after 30 sec without operation
Enclosure
Length x Height x Depth
3.63“ x 3.63“ x 2.35“ (92.2 x 92.2 x 60 mm)
Weight
200 g
Material
Glass Reinforced Plastic (GRP)
Cable entry
Knockout: 2 x 16 mm; 1 x 20 mm
Protection degree
IP 65 / Nema Type 4
Dimensions
A = 3.62“ (92 mm)
F = 2.05“ (52 mm)
B = 3.62“ (92 mm)
G = 2.87“ (72.8 mm)
C = 2.36“ (60 mm)
H = 0.75“ (19 mm)
D = 0.55“ (14 mm)
J = 1.49“ (38 mm)
E = 0.55“ (14 mm)
Ambient conditions - Storage
Temperature
-4 °F to 176 °F (-20 °C to +80 °C)
Humidity, relative
90%, no condensation allowed
Ambient conditions - Operation
Temperature
-4 °F to 176 °F (-20 °C to +80 °C)
Humidity, relative
90%, no condensation allowed
Power requirements
External power supply
10 - 30 V DC. Consumption max. 625 mW. The external power supply will also supply the backlight.
Battery power
1 x 3.6 V AA Lithium battery - life-time depends upon settings and configuration - up to approx. 2 years.
Sensor excitation
Terminal 3
1.2 V for coil pick-up and 3 V for low power pulse signals. Iout=max. 63 µA.
OTE:
N
This voltage shall not be used to supply the flow meter‘s electronics, converters etc., as it will not provide
adequate sustained power! All energy used by the flow meter‘s pick-up will directly influence the battery life-time. It
is strongly advised to use a ‘zero power‘ pickup such as a coil or reed-switch when operating without external power.
It is possible to use some low power NPN or PNP output signals, but the battery life time will be significantly reduced
(consult your distributor).
Terminal 4
8.2 V; Only available when external power is connected.