Installation & Operation Manual
Overview of Setup Functions
Setup Functions and Variables
1
Total
11
UNIT
L, m
3
, kg, lb, GAL, USGAL, bbl, no unit
12
DECIMALS
0, 1, 2, 3 (Ref: displayed value)
13
K-FACTOR
0 000010…9,999,999 (see chart)
14
DECIMALS K-FACTOR
0…6
15
Multiplication factor
x1, x10, x100, x1000, x10000
2
Flow Rate
21
UNIT
mL, L, m
3
, mg, g, kg, ton, GAL, bbl, lb, cf, REV, no unit, scf, Nm
3
, NL, P,
MGAL
22
TIME UNIT
sec, min, hour, day
23
DECIMALS
0, 1, 2, 3 (Ref: displayed value)
24
K-FACTOR
0 000010…9,999,999
25
DECIMALS K-FACTOR
0…6
26
CALCULATION
per 1…255 pulses
27
CUT-OFF
0 1…999 9 secs
3
Display
31
FUNCTION
total, flow rate
4
Power Management (Does Not Apply to This Unit)
5
Flowmeter
51
SIGNAL
npn, npn_lp, reed, reed_lp, pnp, pnp_lp, act_8 1, act_12, act_24
6
Analog
61
OUTPUT
disable, enable
62
4 mA
0000 000…9,999,999
63
20 mA
0000 000…9,999,999
64
CUT-OFF
0 0…9 9%
65
TUNE MIN, 4 mA
0…9,999
66
TUNE MAX, 20 mA
0…9,999
67
FILTER
00…99
7
Pulse
71
PULSE WIDTH
0…250
72
PULSE PER
X,XXX,XXX quantity
8
Communication (Does Not Apply to This Unit)
9
Others
91
MODEL
F100-P
92
TYPE
ER-420LP / ER-420DC / ER-420AC
93
SOFTWARE VERSION
__ __ __
94
SERIAL NO
xxxxxxx
95
PASS CODE
0000…9999
96
TAGNUMBER
0000000…9999999
Page 13
March 2013