External Power Configuration
Remove the two jumpers located at JP1 and JP2 on the module See
In this configuration, the 4…20 mA module
requires power from an external DC power supply The voltage of the external power source must be sufficient to power the
module and drive the loop load The loop loss attributed to the ISO-MOD is 7V DC, so the minimum voltage required to power
a loop can be calculated using the following formula: Loop voltage (min) = (loop load Ohms × 0 02) + 7
OUT (-)
IN (+)
I/O: 4-20 mA
P.N. D020-1045-100
ISO-MOD
JP2
JP1
INT PWR EXT PWR
RTU/PLC
MONITOR
Remove
Jumpers
4-20 mA IN (+)
4-20 mA OUT (-)
Figure 23: Externally powered 4…20 mA