Badger Meter DN15 User Manual Download Page 16

www.badgermeter.com

E-Series, Making Water Visible, ORION, Recordall and RTR  are registered trademarks of Badger Meter, Inc  Other trademarks appearing in this document are the property of their 

respective entities  Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without 

notice, except to the extent an outstanding contractual obligation exists  © 2017 Badger Meter, Inc  All rights reserved  

Making Water Visible®

E-Series® Ultrasonic Meters, Cold Water Meters, DN15, DN20, DN25, DN32, DN40, DN50

The Americas | Badger Meter

 | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400

México | Badger Meter de las Americas, S.A. de C.V.

 | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882

Europe, Eastern Europe Branch Office

 

(for Poland, Latvia, Lithuania, Estonia, Ukraine, Belarus)

 | Badger Meter Europe | ul. Korfantego 6 | 44-193 Knurów | Poland | +48-32-236-8787

Europe, Middle East and Africa | Badger Meter Europa GmbH

 | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0

Europe, Middle East Branch Office | Badger Meter Europe

 | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C209 | Dubai / UAE | +971-4-371 2503 

Slovakia | Badger Meter Slovakia s.r.o. 

| Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01

Asia Pacific | Badger Meter

 | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836

China | Badger Meter

 | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412

Switzerland | Badger Meter Swiss AG

 | Mittelholzerstrasse 8 | 3006 Bern | Switzerland | +41-31-932 01 11

Summary of Contents for DN15

Page 1: ...E Series Ultrasonic Meters Cold Water Meters DN15 DN20 DN25 DN32 DN40 DN50 ESM UM 00255 EN 01 September 2017 User Manual...

Page 2: ...E Series Ultrasonic Meters Page ii September 2017 ESM UM 00255 EN 01...

Page 3: ...Meter 7 Special Fittings and Accessories 7 Installing E Series Ultrasonic Meters 7 Outdoor Installations 7 Indoor Installations 7 Installation Instructions 8 Protect Against Leakage 9 E Series Ultras...

Page 4: ...E Series Ultrasonic Meters Page iv September 2017 ESM UM 00255 EN 01...

Page 5: ...pment PRODUCT UNPACKING AND INSPECTION Upon opening the shipping container visually inspect the product and applicable accessories for any physical damage such as scratches loose or broken parts or an...

Page 6: ...al and reading Verify that a suitable electrical grounding wire is properly attached to the upstream and downstream pipe connections of the meter The grounding wire provides an alternative path for an...

Page 7: ...edded to ensure that it is not axially misaligned and that it lays evenly on the bottom of the pipe trench The backfill material covering the pipe should be placed appropriately to maintain pipe align...

Page 8: ...e nut against the meter spud end When the first threads on both the nut and the spud end coincide you will hear a slight click and feel the nut move into the starting position iii Tighten the nut by h...

Page 9: ...cape 7 Once water is flowing normally turn off the faucet E SERIES ULTRASONIC METER OPERATIONS Meter Display The Badger Meter E Series Ultrasonic meters use a nine digit Liquid Crystal Display LCD tha...

Page 10: ...feet or 100 thousand cubic meters with a resolution of 0 0001 cubic meters For DN40 and DN50 meters totalized flow displays up to 100 million gallons with a resolution of 0 1 gallons 10 million cubic...

Page 11: ...345678 10 gallons 123456 10 gallons 1234567 100 gallons 12345 100 gallons 123456 Typical Billing Units 1000 gallons 1234 Typical Billing Units 1000 gallons 12345 Cubic Feet Meter reading 1000th ft3 12...

Page 12: ...ding 7 digit reading Itron 100W 8 9 digit reading 6 digit reading 7 digit reading Itron 100W 9 digit reading 6 digit reading 7 digit reading No longer for sale 100W will transmit 9 digits through Itro...

Page 13: ...rm is sent to the endpoint NOTE No consumption data is sent to endpoint when the alarm is active Consumption data is sent to the endpoint except when Exceeding Max Flow alarm is set Reverse flow The m...

Page 14: ...o provide long term service with no maintenance The enclosure which includes the electronic meter s ultrasonic sensors battery and display is completely potted permanently sealed and non removable E S...

Page 15: ...m3 hr 4 0 gpm 1 71 m3 hr 7 5 gpm 1 71 m3 hr 7 5 gpm 1 71 m3 hr 7 5 gpm 3 2 m3 hr 14 0 gpm 4 5 m3 hr 20 gpm R Value 250 250 250 250 250 250 250 Operating Performance In the normal temperature range of...

Page 16: ...de C V Pedro Luis Ogaz n N 32 Esq Angelina N 24 Colonia Guadalupe Inn CP 01050 M xico DF M xico 52 55 5662 0882 Europe Eastern Europe Branch Office for Poland Latvia Lithuania Estonia Ukraine Belarus...

Reviews: