11
ASSEMBLY INSTRUCTIONS
11
12
11. Propane Only-Proper Hose Connection.
WARNING!
Ensure the hose does not contact any high
temperature surfaces, or it may melt and leak causing
a fire.
12. Connect hose and regulator to cylinder.
The propane gas and cylinder are sold separately.
Use a standard 20 lb. propane cylinder only.
Use this heater only with a propane vapor withdrawal
supply system. See chapter 12 of the standard for
storage and handling of liquefied petroleum gas,
ANSI/NFPA 58. Your local library or fire department
should have this book.
A minimum supply pressure of 0.4 p.s.i. is required for
the purpose of input adjustment for propane gas.
Storage of an appliance indoors is permissible only if
the cylinder is disconnected and removed from the
appliance. A cylinder must be stored outdoors in a
well-ventilated area out of the reach of children. A
disconnected cylinder must have dust caps tightly
installed and must not be stored in a building, garage
or any other enclosed area. The minimum permissible
gas supply pressure of 10 W.C. is required for purpose
of input adjustment. The minimum hourly of 17000 Btu
is required input rating for a heater for automatic
operation at ratings less than full input rating. The
pressure regulator and hose assembly supplied with
the appliance must be used. The installation must
conform with local codes, or in the absence of local
codes,with national fuel gas code, ANSI Z223.1
/NFPA54, natural gas and propane Installation Code,
CSA B149.1, or propane storage and handling code,
B149.2.
Standard 20 lb. tank