2 Introduction

General Description

The Tru Pointe

®

 Ultra Ultrasonic Leak Detector is an electronic instrument that detects the 

inaudible high frequency sound (ultrasound) of high pressure leaks and converts it to sound a 
human can hear.  Using patented technology, the Tru Pointe

®

 Ultra guides the user to a leak by 

quantifying the intensity of the ultrasound and converting it to sound the user can easily hear.

The Tru Pointe

®

 Ultra has been speci

fi

 cally designed for air conditioning and refrigeration 

(HVAC-R) leak detection.  The Tru Pointe

®

 Ultra is the only test system that can simultaneously 

detect the vacuum and high pressure leaks that can occur in HVAC-R systems.  Since the instru-
ment detects only sound, it is gas-independent and can be used to detect leaks at the speed of 
sound, without the delay seen with gas dependent “sniffers.”

What’s in the Kit

28-8000  

Tru Pointe

®

 Ultra ....................... 28-7000  

Instruction Manual .................... 28-9000  
Carrying Case........................... 28-0005  
6” Wave Guide .......................... 28-0004  
Touch Probe ............................. 28-0003  
Folding Hi-Fi Headset 
w/ Volume Control .................... 28-0002  
9v Battery ................................. 204-0024 

 

Warranty Card .......................... 06-8825

3 Specifi cations

Physical

Dimensions

4.15”L X 2.4”W X .875”D (105 mm 
X 61 mm X 22.22 mm)

Overall Length

5.5” (140 mm)

Body Material

ABS

Body Finish

Blue ABS

Connector

3.5 mm Stereo

Weight

0.3 lb. (138 g) including battery

Electrical

Sensitivity

-80 db/V-

μ

bar

Detection Performance

1.5oz/year refrigerant

Ultrasound Converter Type

Heterodyne

Frequency Response

36kHz to 42kHz

Heterodyne Oscillator

Analog

Heterodyne Filter

4kHz

Controls

1 Button

Sensitivity Control

Continually Variable Slide

Output, Audio

0Hz to 4kHz

Output, Visual

10 Element LED Bar Graph

Battery Type

9 Volt

Run Time

80-120 hours

28-8010

Tru Pointe

®

 Ultra ....................... 28-7000

SoundBlaster

®

 .......................... 28-7006

Instruction Manual .................... 28-9000 
Carrying Case........................... 28-0005 
6” Wave Guide .......................... 28-0004 
Touch Probe ............................. 28-0003 
Folding Hi-Fi Headset 
w/ Volume Control .................... 28-0002 
9v Battery ................................. 204-0024
Warranty Card .......................... 06-8825

Features

• 

Capable of detecting a 5 psi leak from a .005” hole from 20-30 feet (depending on back-
ground noise.

• 

Capable of detecting any gas that generates ultrasonic sound during 

fl

 ow, including vacuum 

leaks.

• 

Not affected by wind or high concentrations of leaked refrigerants.

• SoundBlaster

®

 allows testing of items not under pressure. (28-8010 only)

Summary of Contents for Tru Pointe Ultra

Page 1: ...Tru Pointe Ultra Ultrasonic Leak Detector Instruction 28 9000 Operation and Maintenance Rev 0 May 2010 The Measurable Difference ...

Page 2: ...itness for a particular purpose or application No statements or recommendations contained herein are to be construed as inducements to infringe any relevant patent now or hereafter in existence Bacharach neither assumes nor authorizes any representatives or other person to assume for it any obligation of liability other than such as expressly set forth herein Under no circumstances shall Bacharach...

Page 3: ...the warning symbol at left in this manual denotes a potential hazard associ ated with the use of this equipment It calls attention to a procedure practice or condition or the like which if not correctly performed or adhered to could result in personal injury or death Caution Statements The use of the word CAUTION and the caution symbol at left in this manual denotes a potential hazard associ ated ...

Page 4: ...3 Folding Hi Fi Headset w Volume Control 28 0002 9v Battery 204 0024 Warranty Card 06 8825 3 Specifications Physical Dimensions 4 15 L X 2 4 W X 875 D 105 mm X 61 mm X 22 22 mm Overall Length 5 5 140 mm Body Material ABS Body Finish Blue ABS Connector 3 5 mm Stereo Weight 0 3 lb 138 g including battery Electrical Sensitivity 80 db V μbar Detection Performance 1 5oz year refrigerant Ultrasound Conv...

Page 5: ... vacuum into a system The sound made by leaks refrigerant compressed air tire leak etc is mostly ultrasonic and cannot be heard by humans The following describes how to effectively determine the location of an airborne leak using the Tru Pointe Ultra 1 Press the On Off Button If there is significant background noise and the LED Bargraph Display reads 10 reduce the sensitivity until the LED s disap...

Page 6: ...n a tight or inaccessible area use the supplied 1 4 tubing to deter mine the leak location Longer sections of 1 4 tubing can be used at the expense of sensitivity 3 Use as much pressure in the system as is safely possible to facilitate locating the leak Using the Touch Probe The patented Touch Probe accessory is a device that converts solid borne sounds into airborne sound the Tru Pointe Ultra can...

Page 7: ...ce 800 736 4666 or 724 334 5000 to obtain an RMA number for service returns When you receive your RMA number return the instrument postage paid and insured to Bacharach Inc 9227 E Lincoln Ave Suite 200 Lone Tree CO 80124 USA Email help mybacharach com Using the SoundBlaster Some Tru Pointe Ultra kits include Bacharach s ultrasonic sound generator the SoundBlaster The SoundBlaster is used to artifi...

Page 8: ...Tru Pointe Ultra Instruction 28 9000 10 11 Tru Pointe Ultra Instruction 28 9000 NOTES NOTES ...

Page 9: ...Bacharach Inc Phone 724 334 5000 Toll Free 800 736 4666 Fax 724 334 5001 www mybacharach com help mybacharach com The Measurable Difference ...

Reviews: