MVR-300™ Refrigerant Gas Detector
46
P/N: 6203-9000 Version 1
Figure 28. Typical Grounding Lugs on Custom Metal Cover Plate and UK Back Box
10.5 Customizing Face Plates
The UK version of the MVR-300 requires a customized faceplate (not supplied by Bacharach) that
provides proper access holes for airflow to the sensor module and visual access to the LED indicator at a
minimum. Optional holes for the two magnetic contact points will prevent the need to remove the
faceplate for local programming and operation of the MVR-300, but are not required.
NOTICE
If the drill pattern of the customized (metal) faceplate does not accommodate the two
magnetic switch locations, the faceplate must be removed to use the magnetic wand
functions (e.g., zero adjustment, span adjustment, alarm latching, alarm silencing, etc.).
Figure 29. Sample Customized Faceplate with LED and Sensor Cutouts
NOTICE
For specifications and recommended drill patterns for customizing a UK faceplate that
properly aligns with the MVR-300 UK, visit the MVR-300 product page at
www.
.com
1.800.561.8187