background image

Combustible Gas Leak Detector

Instruction 19-9336

Rev. 1 – November 2010

Audible Alarm

• 

Instrument Ready -

 Slow beep. The beep 

rate is about once per second with no gas 
detected.

• 

Combustible Gas Indication -

 Beeps at 

a rate that increases along with the gas 
concentration.

• 

Sensitivity -

 Produces an 

increasing

 

frequency tone when sensitivity changes 
from low to high, and produces a 

decreasing

 

frequency tone when sensitivity changes 
from high to low.

• 

Dead Batteries -

 High frequency tone, fol-

lowed by the instrument turning itself OFF.

• 

Sensor Error -

 Rapidly changing high and 

low frequency tones.

Visual Alarm LED

• 

Power ON - 

Rapidly fl ashes green during warm-

up (approximately 60 seconds).

• 

Power OFF -

 Glows red just before power OFF.

• 

Instrument Ready -

 Slowly fl ashes green. The 

fl ash rate is about once per second with no gas 
detected.

• 

Combustible Gas Indication -

 Flashes green at 

a rate that increases with the gas concentration.

• 

Sensitivity Change -

 Color changes from red to 

green.

• 

Low Battery -

 Flashes orange instead of green 

when checking for gas leaks. Typically 1 hour 
of operation left after LED changes to orange. 
Change batteries as soon as convenient.

• 

Dead Batteries -

 Glows red, followed by the 

instrument turning itself OFF.

• 

Sensor Error -

 Flashes alternating green and red.

One Button Control

•  Press once for half second to turn instrument ON.

•  Press and hold for 2 seconds to turn instrument OFF.

•  Double press to toggle sensitivity between high and low.

Combustibles Sensor 
& Sensor Cover

Battery Door

12 Inch
Flexible Probe

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]