background image

55-8001

Gas Hunter Kit includes: 4’ polyurethane

coiled hose with 10” aluminum probe

assembly. 3 AA alkaline batteries, laminated

methane/pressure reference

card and 2 inlet filters.

55-3001

30” plastic bar hole probe

3474-1210

30” aluminum bar hole probe

55-0063 

Water trap/filter assembly for

barholing applications

55-8005 

Flue probe assembly with sample and 

draft lines, a water trap/filter assembly and

quick connect fittings

24-1107 

Water trap/filter assembly for flue 

probe 55-8005

07-1644 

Filters, package of 3 for 24-1107 water trap 

and 55-0063 water trap

55-7100 

Foam filters for standard 10" aluminum

probe assembly and barhole probes.

Box of 10

55-7400 

Charcoal filters for standard 10"

aluminum probe assembly and barhole

probes. Box of 10

55-0045 

Inlet filters for instrument (package of 2)

55-0046 

Gas samping tubing coupler

55-0038

Pressure tubing assembly with

1/8” quick connect socket

55-0087 

Soft carrying case w/strap

55-0039 

Hard ABS plastic carrying case

55-8002 

Calibration kit (less calibration gas)

includes on-demand regulator, 3 feet

of 1/4" tubing, and a quick-connect female

fitting

55-0068 

Calibration gas, 2.5% Methane,

100 ppm CO, 18.5 O

2

in Nitrogen,

103 L Tank 

55-0060 

Calibration gas, 100% Methane,

58 L Tank

51-7131 

Calibration gas, zero air, 20.9% O

2

in air, 

103 L Tank

51-1121 

Calibration gas, 2.5% Methane in air,

103 L Tank

51-1994 

Calibration gas, 100 ppm Carbon 

Monoxide in air, 103 L Tank

55-0040 

Combustible gas sensor

54-7001 Oxygen 

sensor

54-7003 

Carbon monoxide sensor

Part #

Description

Specifications

Ordering Information

©June 2002, Bacharach, Inc., all rights reserved. All information herein is
subject to verification. Product Catalog 4161. 6/02 5M HMC. Printed in U.S.A.

The Gas 

Hunter

includes a 10" gas

sampling probe, coiled gas tubing with
quick-connect fittings, 2 inlet filters, 3
AA batteries and a pocket size pressure
and gas conversion card. In addition, a
wide range of accessories are available
such as a hard carrying case, a soft
carrying case, a service line pressure
kit, a flue probe, a water trap and 30"
barhole probes.

Size

4.7 x 2.3 x 4.35 inches  (11.9 x 5.8 x 10.9 cm)

Batteries

3 - AA disposable alkaline batteries

Measurement
Ranges

Natural Gas

PPM: 0 - 2500 ppm

LO%: 0.2 to 5.0%

vol. gas

HI%:  0 to 100% 

vol. gas

Accuracy

Natural Gas 

LO%:  ± 0.3% gas
HI%:   ± 3% gas

Pressure

± 3% or ± 0.2 in H

2

O

of reading, whichever
is greater

- 4 to +122˚ F (-20 to 50˚ C)

10 to 90% R.H. (non-condensing)

Operating
Environmental
Conditions

Weight

29 ounces (822 grams) without probe assembly

Warm Up Time

1 minute

Response Time

Gas: 20 seconds to 95% of final value

O

2

: 20 seconds to 95% of final value

CO: 20 seconds to 95% of final value

Pressure: < 3 seconds to 95% of final value

Battery Life

Typically 6-8 hours of continuous operation

Agency
Approvals

MET lab certified to UL913 and CSA C22.2-157,
intrinsically safe for use in Class I, Division 1,
Groups A, B, C & D hazardous areas

Warranty

1 year, including sensors

Carbon Monoxide

0 - 1000 ppm in 
1 ppm increments

Oxygen

0.0 - 25.0% vol.

CO Air-Free 

0 - 9,999 ppm

Pressure/Draft

Pressure

: 0.0 - 27.7 in H

2

O

Draft

: autoranges between

–0.01 to –0.99,
–1.0 to –9.9
–10 to –28 in H

2

O

Carbon Monoxide

± 5% of reading or 
± 3ppm, whichever
is greater

Oxygen

± 0.5% O

2

Case Material

Anodized aluminum extrusion with rubber
bumpers on end caps

Calculated
Ranges

Reviews: