Fyrite
InTech
Manual
Configuration
0024-9486 Rev 2
25
Setup Menu
Function
WARNING:
DO NOT use the Fyrite
InTech
to sample gas from an oil-based
combustion system without first doing a
smoke test and adjusting your combustion
process as needed. Smoke test results of
greater than 1 indicate improper
combustion, and demonstrate the need
for process adjustment. Only use the
Fyrite
InTech
to sample flue gas AFTER
the combustion process is adjusted and
the smoke test indicates a smoke level of 0
or 1.
Oil Derivative (Siegert only) specifies whether or not oil
derivatives were present during the smoke tests (see
page 24).
For incomplete combustion, oil derivatives present in
the sample can be precipitated onto the filter paper,
causing a color change in the smoke spot.
Use the UP (
) and DOWN (
) arrow buttons to select
the YES option if oil derivatives were present during
the smoke test. Otherwise select NO and press ENTER.
This information is included on printouts.
Summary of Contents for Fyrite INTECH
Page 4: ...Fyrite InTech Manual iv 0024 9486 Rev 2...
Page 11: ...Fyrite InTech Manual Overview 0024 9486 Rev 2 5 1 6 Components...
Page 12: ...Overview Fyrite InTech Manual 6 0024 9486 Rev 2...
Page 16: ...Overview Fyrite InTech Manual 10 0024 9486 Rev 2...
Page 70: ...Declaration of Conformity Fyrite InTech Manual 64 0024 9486 Rev 2...