Bacharach ECA 450 Specifications Download Page 2

Headquarters: 621 Hunt Valley Circle,  New Kensington, PA  15068  U.S.A.

Phone: 1-800-736-4666     Canada: 1-800-328-5217     E-Mail: [email protected]     Website: www.bacharach-inc.com

TECHNICAL DATA

Measurements & Ranges

Oxygen

0.1 to 20.9%

Carbon Monoxide

0 to 4000 ppm

(hydrogen compensated)

(hydrogen compensated)

Carbon Monoxide (high)*

4001 to 80000 ppm

Nitric Oxide*

0 to 3500 ppm

Nitrogen Dioxide*

0 to 500 ppm

Sulfur Dioxide*

0 to 4000 ppm

Combustibles*

0 to 5.00% (application dependent)

Stack Temperature

-4 to 2400 degrees F (-20 to 1315˚C)

Primary/Ambient Temperature

-4 to 999 degrees F (-20 to 999˚C)

Pressure/Draft

-27.7 to 27.7 inches of H2O

Calculations & Ranges

Combustion Efficiency

0.1 to 100.0%

Excess Air

1.0 to 250%

Carbon Dioxide (dry basis)

0 to fuel dependent maximum

NO

X

 (NO

X          

=NO+NO

2

)

0 to 4000 ppm

NO

referenced to % O

2

0 to 17000 ppm

CO referenced to % O

2

0 to 99999 ppm

NO referenced to % O

2

0 to 14900 ppm

NO

2

 referenced to % O

2

0 to 2100 ppm

SO

X

 referenced to % O

2

0 to 17000 ppm

Accuracy

Oxygen

±

 0.3% O2 on practical concentrations of flue gas

Stack or Flue Gas Temp.

±

 4

°

F between 32 and 255

°

F

(

±

 2

°

C between 0 and 124

°

C)

±

 6

°

F between 257 and 480

°

F

(

±

 3

°

C between 125 and 249

°

C)

±

 8

°

F between 482 and 752

°

F

(

±

 4

°

C between 250 and 400

°

C)

Primary-air/ambient Temp.

±

 2

°

F between 32 and 212

°

F

(

±

 1

°

C between 0 and 100

°

C)

Pressure Draft

±

 2% of reading or 

±

 .02 in wc whichever is greater

CO

±

 5% of reading or 

±

 10 ppm whichever is greater between

0-2000 ppm CO

±

 10% of reading between 2001 to 40000 ppm CO

NO

±

 5% of reading or 

±

 5 ppm whichever is greater between

0-2000 ppm NO

NO

2

±

 5% of reading or 

±

 5 ppm whichever is greater between

0-500 ppm NO

2

SO

2

±

 5% of reading or 

±

 10 ppm whichever is greater between

0-2000 ppm SO

2

HC

±

 5% of full scale

Selectable Fuels

Natural Gas, Oil #2, Oil #4, Oil #5, Oil #6,
Propane, Coal, Wood, Kerosene, Bagasse

Power

Universal AC adapter and an internal battery pack.  Adapter will
accept input voltages from 100 to 240V. Fully charged battery
pack provides a minimum of 8 hrs of operation

Pumps & Probe

Two pumps are included. The first pump supplies gas sample
to the sensors. The second pump supplies fresh air to purge
the low range CO sensor when CO levels exceed 4000 ppm.
Probe includes a standard probe and hose assembly equipped
with a water trap, particulate filter, probe stop, 15 feet of hose,
and 12-inch probe tube.

Size

13.5” H x 18.5” W x 9” D

Weight

25 lbs. (11.34 kg)

Warranty

1 year, extended warranty available

* Optional

Applications

The ECA 450 is ideal for professionals concerned about combustion
efficiency, environmental compliance, or both.  It enables plant
maintenance engineers and managers, industrial boiler/furnace service
technicians, energy coordinators, compliance officers, environmental
auditors and safety managers to ensure that industrial equipment is
burning efficiently while environmental regulations are being met.

The maximum operating temperature for probes included in 24-7221, 24-7224, 24-7223,
24-3024 and 24-3025 is 1472

°

F (800

°

C).  The maximum operating temperature for high

temperature probes 24-3035, 24-3036 and 24-3037 is 2000

°

F (1093

°

C).

Bacharach is a registered trademark of Bacharach, Inc.
© 2003, Bacharach, Inc.  All rights reserved. All information herein is subject to verification.
Product Bulletin-4138 08/03 10M DXC HPC
Printed in U.S.A.

ORDERING INFORMATION

PART NO.

DESCRIPTION

24-7221

Base Unit (O

2

, CO, T

s

, T

a

, DP)

24-7289

Base Unit (O

2

, CO, T

s

, T

a

, DP) w/ wireless hand-held remote

24-7223

Heavy duty sample conditioning system (EPA/ETV Test Verified

performance). Includes Peltier chiller unit with integral condensate pump,

15’ heated hose assembly with probe and built-in temperature controller

24-8400

NO

X

 Kit with NO / NO

2

 sensors and compact sample conditioner

24-8401

NO

X

 and SO

X

 Kit with NO, NO

X

 and SO

2

 sensors and compact

sample conditioner

PART NO.

REPLACEMENT SENSORS

24-0788

O

2

 Sensor

24-0789

CO (low) Sensor

24-0997

CO (high) Sensor

24-0881

NO Sensor

24-1055

Combustible Sensor

24-1027

NO

2

 Sensor

24-0998

SO

2

 Sensor (requires NO

2

 option)

PART NO.        MODULAR SENSORS (For Factory Installation in Base Unit)

24-3206

CO (high) Sensor

24-3207

NO Sensor

24-3209

NO

2

 Sensor

24-3030

SO

2

 Sensor

24-3028

Combustible Sensor

PART NO.        ACCESSORIES

07-1644

Filters (pkg. of 3)

24-7059

Calibration Kit (does not include gas)

104-4027

Serial Cable DB.9M to DB.9F

24-0980

Printer Paper (5 rolls)

Distributed By:

Reviews: