Bacharach 19-7037 Instructions Manual Download Page 7

5

4.6

Interpreting the Display

Gas Display

The LCD directly shows O

2

 levels in the range from

0 to 25%.  The display on the right indicates a O

2

level of 20.9%.

4.4

Using the Strap

The instrument's elastic strap allows the unit to be either hand-held, or
hung on nearby objects.

By sliding your hand between the instrument and its elastic strap, you
can hold onto the Oxor II with a minimum of effort. The instrument's
front panel slide switches can then be actuated by your thumb for one-
handed operation. Or, by releasing the metal clip at the bottom of the
instrument's case, you can hang the instrument by its strap on nearby
objects such as nails, sheet metal, or valve handles.

4.5

Using the Probe

The basic probe, or the optional rigid stainless steel probe with handle,
connected to a flexible hose with sample filter can be used to draw a
gas sample into the instrument from the room, grilles, diffusers,
furnace flues, hot-water heater flues, and from inside furnaces heat
exchangers.

Both hose and probe are detachable from the instrument when sam-
pling without the probe, or when sampling with a different probe is
desired.

Important: 

If condensation is observed within the hose, do not  allow

water level to build up to a point where it cuts off flow.

Summary of Contents for 19-7037

Page 1: ...n Analyzer Part No 19 7037 19 7044 Rev 6 October 1999 Bacharach Inc 621 Hunt Valley Circle New Kensington PA 15068 PH 724 334 5000 FAX 724 334 5001 Web www bacharach inc com E mail help bacharach inc...

Page 2: ...icalsensors arewarrantedforaperiod of six months THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN AND ACCEPTED IN LIEU OF I ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITA...

Page 3: ...ory or training assistance should be obtained before use Assistance is available by calling your nearest Bacharach Service Center 1 INTRODUCTION TheOxor IIisacommercial gradepor tableinstrumentdesigne...

Page 4: ...observ ingproperbatterypolarity installfour C size batteriesintotheinstrument sbatterycompart ment Recommended battery types Duracell Alkaline or equivalent After the batteries are installed replace t...

Page 5: ...trument s electronic circuitry The instrument will operate once batteries are properly installed and the PTC thermistor is allowed to cool 3 2 Probe Installation Install the probe by sliding the end o...

Page 6: ...abilizes Turn off the instrument by sliding the POWER switch to OFF 4 2 Adjusting the Instrument After being turned on and warmed up for at least 1 minute the instrument should indicate 20 9 in fresh...

Page 7: ...the metal clip at the bottom of the instrument s case you can hang the instrument by its strap on nearby objects such as nails sheet metal or valve handles 4 5 Using the Probe Thebasicprobe ortheoptio...

Page 8: ...eds to be calibrated at regular intervals to ascertain that it still meets its accuracy specification A regular calibration schedule should be established Detailed calibration maintenance procedures a...

Page 9: ...lds Court Unit 3 Markham Ontario L3R 9W7 Canada Phone 905 470 8985 Fax 905 470 8963 E mail bachcan idirect com M xico Bacharach de M xico Playa Regatas No 473 Tercer Piso Col Militar Marte Delegaci n...

Page 10: ...Notes 8...

Reviews: