background image

Dokumentation 

INTERCOM

MODULE

 

Introduction

 

 

 

INTERCOM

MODULE 

BAB TECHNOLOGIE GmbH  7 

 

 

TECHNICAL DATA 

1.3

Article No. 10582 (IP)  

 

 

Operating voltage: 12–32V DC 

 

Typical power consumption: 300 mA / 12 V DC 

 

Power consumption: <= 5 W 

 

Connection: Power supplier over screw-type terminal 

 

Resistant to climate: EN 50090-2-2 

 

Ambient temperature: –5 to + 35 °C 

 

Rel. humidity (non-condensing): 5 % to 80 % 

 

Mechanical data 

 

Mounting: DIN-rail housing 4 units 

 

Dimensions (W x H x D) in mm: 72 x 90 x 63 

 

Housing: Plastic 

 

Protection class: IP20 (according to EN 60529) 

 

Interfaces: 

 

Ethernet over RJ45-feamle connector 

 

Specific features 

 

Software requirement 

 

Operating system: independent 

 

Communication: Network interface 

 

Browser: current standard browser 

 

 

 

SCOPE OF DELIVERY AND INTERFACES 

1.4

The 

INTERCOM

MODULE will be delivered in carton with the following contents: 

 

 

1x 

INTERCOM

MODULE 

 

1x screw-type terminal  2-way power supplier 

 

A power supply unit for the device is NOT included in the scope of delivery! 

 

In addition to the connection for the power supply (

12-32 V DC

), the 

INTERCOM

MODULE has the 

following interfaces 

 

 

1x RJ 45: Ethernet 100Mbit/s Full Duplex 

 

4x USB-terminal (not supported) 

 

Factory setting by delivery 

 

IP-address 

192.168.1.221 

 

User name 

admin 

 

Password 

admin 

 

Device Name 

INTERCOM

MODULE 

 

 

Summary of Contents for INTERCOMMODULE

Page 1: ...BAB TECHNOLOGIE GmbH INTERCOMMODULE Documentation Version 1 0 2 Type IP Item No 10582 Manual version I Issue 08 2019 Date 28 Aug 2019 EN...

Page 2: ...ion Documentation INTERCOMMODULE 2 BAB TECHNOLOGIE GmbH INTERCOMMODULE BAB TECHNOLOGIE GmbH H rder Burgstra e 18 D 44263 Dortmund info bab tec de Tel 49 0 231 476 425 30 Fax 49 0 231 476 425 59 www ba...

Page 3: ...the Network settings of the INTERCOMMODULE 14 3 4 4 Configuration INTERCOMMODULE 17 Saving the configuration 17 4 1 General 17 4 2 Network 18 4 3 User administration 19 4 4 Remote servicing 19 4 5 Ba...

Page 4: ...on 19 Figure 14 Remote servicing 20 Figure 15 Backup restore 21 Figure 16 Configuration system 23 Figure 17 Keep network configuration 23 Figure 18 Perform update 23 Figure 19 INTERCOMMODULE configura...

Page 5: ...w you get to know the INTERCOMMODULE quickly and comprehensively In addition the operating manual is given you advices for installing and using your new device BAB TECHNOLOGIE Figure 1 INTERCOMMODULE...

Page 6: ...sh whether the video door station is a SIP server or a SIP client A SIP server is e g the ABB Welcome The ABB Welcome has an IP gateway 83342 that works as a server where it is required to be log in a...

Page 7: ...faces Ethernet over RJ45 feamle connector Specific features Software requirement Operating system independent Communication Network interface Browser current standard browser SCOPE OF DELIVERY AND INT...

Page 8: ...y can be connected easily the screw type terminals see figure below can be taken off Now the cable of the power supply is connected to the screw type terminals see figure below Please observe the pola...

Page 9: ...play Status OFF The device is booting Flashing GREEN The device has been started the LED simulates a heartbeat The flashing interval increases depending on the device utilisation Explanation The green...

Page 10: ...e name INTERCOMMODULE Note The password must be changed immediately when logging in for the first time If the password is lost the device cannot be reset LANGUAGE 3 1 Web interface The language used f...

Page 11: ...djusted to the address range where necessary Please follow the information given in the chapter Adjusting the network setting of your computer for this purpose 3 3 1 ADJUSTING THE NETWORK SETTINGS OF...

Page 12: ...protocol Version 4 TCP IPv4 and click Properties again Figure 5 Properties of the LAN connection Now note down the current IP address settings or take a screenshot in order to ensure that you can rese...

Page 13: ...the Windows Network and Sharing Centre Settings window is shown Thus you have adjusted the network settings of your PC to those of the INTERCOMMODULE You can access the web interface of the INTERCOMM...

Page 14: ...the INTERCOMMODULE in the address line of your browser for factory settings 192 168 1 221 Figure 7 INTERCOMMODULE web interface log in The start page of the INTERCOMMODULE opens Click on Log in on the...

Page 15: ...he gateway entry are correct Often the IP address of the WLAN router Note Without a correct gateway entry the device will not be able to communicate with the Internet DNS server DNS is the abbreviatio...

Page 16: ...In order to save the settings made click Save Configuration The server in the device is restarted the browser automatically connects to the new IP address if possible Note Please bear in mind that yo...

Page 17: ...sign an individual device name for your INTERCOMMODULE This name is then displayed in the Discovery Tool and BAB STARTER System time The current system time of the device is shown Clicking the button...

Page 18: ...work administrator as to which settings are to be carried out Please note that an IP address may never be assigned twice DNS server DNS is the abbreviation for Domain Name System The DNS server conver...

Page 19: ...User administration REMOTE SERVICING 4 5 Remote Servicing is available as of firmware version 1 3 7 Activate the Remote Servicing Access of the INTERCOMMODULE Select a time between 2 12 hours after wh...

Page 20: ...Configuration INTERCOMMODULE Documentation INTERCOMMODULE 20 BAB TECHNOLOGIE GmbH INTERCOMMODULE Figure 14 Remote servicing Before you activate Remote Servicing Access contact Support...

Page 21: ...15 Backup restore CREATING BACKUP Select the checkboxes under Modules to set which configuration data is to be backed up Configuration All configuration data of the INTERCOMMODULE Note The network set...

Page 22: ...rmware version and Comments fields Configuration All configuration data except for the app configuration data Note The network settings are not part of the backup file SYSTEM FIRMWARE UPDATE 4 7 SERVI...

Page 23: ...yed Please choose one of the update options 1 Keep Configuration All settings apps and instances will be preserved 2 Keep Network Settings Only the network settings will be preserved Caution all other...

Page 24: ...until the update is complete The Web interface is updated automatically once the process has been successfully completed The update restores the device factory settings except for the network settings...

Page 25: ...nufacturer and integrated into the network The following examples will be described only the settings in software of manufacturer which are important for the INTERCOMMODULE If you have any questions a...

Page 26: ...eway ABB Welcome IP gateway the IP address of the gateway as well as the user name and password of this gateway must be entered This data requires the INTERCOMMODULE to log in to the gateway The IP ga...

Page 27: ...utstations INDOOR STATIONS 5 2 Here you can configure one or more indoor stations Windows client with CONTROL T 2 Click on Add to connect an indoor station via its individual SIP ID to the INTERCOMMOD...

Page 28: ...entation of the outdoor system Click on Add to connect a call button via its individual SIP ID to the associated outdoor station Continue to assign the call button to the already configured indoor sta...

Page 29: ...telephone number That SIP account will be needed later in CONTROL T 2 6 A SIP password is not required 7 Allow incoming calls Other settings are not required for the INTERCOMMODULE Save the settings...

Page 30: ...button you want to configure 14 Assign a freely selectable display name 15 Choose a validity type In each validity type you have to activate SIP 16 Weekly schedule 17 Select in weekly schedule the ca...

Page 31: ...4 7 If you set other activation times in the weekly schedule or select a different validity type please note that DoorBird does not establish a connection via SIP to the INTERCOMMODULE during the deac...

Page 32: ...gs must now be done in the 2N web interface 1 Log in to the web interface of your 2N 2 Navigate to services phone and configure the SIP see Figure 26 SIP configuration 2N Identity of the intercom Disp...

Page 33: ...you limit the time of the SIP phone calls that no SIP call is forwarded to the INTERCOMMODULE during this time Helios IP Eye address Isn t necessary for the operation of the INTERCOMMODULE Parallel ca...

Page 34: ...Configuration examples Documentation INTERCOMMODULE 34 BAB TECHNOLOGIE GmbH INTERCOMMODULE Figure 28 Configuration HTTP API...

Page 35: ...n that the IP gateway gets a different IP address than what you entered during the configuration These must be checked and re entered in case of a faulty connection Figure 29 Welcome IP gateway networ...

Page 36: ...he middle and right potentiometer indicate the address of the upper bell button of the outdoor station The underlying bell buttons are numbered from top to bottom in order Thus for this example a SIP...

Page 37: ...Dokumentation INTERCOMMODULE Configuration examples INTERCOMMODULE BAB TECHNOLOGIE GmbH 37 Parameter ICM ods...

Reviews: