Safety sensors
Machines built from May 2012 have magnetic safety sensors as standard.
The sensors comprise two parts, (1) a magnet and (2) a
sensor, which need to be aligned for correct working. Please
refer to photograph A.
Failure of the magnetic safety sensors can be the result of:
Opening and closing the guard too quickly;
Opening and closing the guard only a short distance;
Closing the guard with a slamming action;
To rectify this situation the following steps should be taken.
Open the guard fully and close it in a controlled
manner;
Turn off the power supply for 10 seconds and then
restore power;
Machines built after November 2014. Depress the
top most button on the control unit for 3 seconds.
Please refer to the photograph B.
1
2
A
B