BA Pumps & Sprayers TSX400 Series Safe Operating Procedures Download Page 7

0800 833 538 

www.bapumpsandsprayers.com

TSX400 PA430

Tank:

 400 litre UV stabilized and impact resistant polyethylene tank.

Pump: 

Bertolini PA430 pump, 40 lpm and 580 psi

Engine:

 Honda GX160

Hose & Reel:

 50 metre maxi reel

Spray Gun:

 SPOT300

Filter:

 Arag 32mm, 50 Mesh Filter 

Controls:

 Karin two tap pressure regulator with 40 BAR spring

Recommended Operating Pressure:

 Spot Spraying: 100-400 psi Boom: 1-6BAR 

 

XP Kit: 1-3 BAR

Installation

Unpack the sprayer and check all parts are included and nothing is damaged. Items  
included for each model are listed in the below chart.

Item

 

    

12 VOLT 

 POLY2030 

 PA430

Tank with pump

            

Battery cable assembly

     

Spray Hose & Reel

 

Spray Gun

                

Operators manual

  

  

          

PLEASE CHECK VEHICLE MANUFACTURERS SPECIFICATIONS FOR COMPATIBILITY  

BEFORE FITTING YOUR SPRAYER 

Connection to 12-volt DC supply (12 Volt Model Only)

The sprayer requires a 12-volt DC power source. A 2-metre loom is provided to allow the 
sprayer to be connected to the 12-volt DC battery.  The red wire is positive and the black is 
negative. An on/off switch is fitted to the sprayer to allow the sprayer to be disconnected 

from the 12-volt source to prevent the accidental drain of power.  The switch also allows the 
pump to be shut down when the tank is empty preventing overheating and damage to the 
pump.  It is recommended that if installing the sprayer on an UTV or any vehicle that a 10 
amp fuse be installed to prevent any potential damage to the electrical system on the  

vehicle.  Consult your vehicle instruction manual for the correct electrical connection.

To avoid damage to the pump ensure 

the red wire is connected to the  

positive battery terminal.

To avoid fire do not remove the fuse 

and ensure the wiring loom is not 

located near hot engine parts or the 

exhaust.

X

  

X

  

Summary of Contents for TSX400 Series

Page 1: ......

Page 2: ...ay tanks or other equipment must be filled only to a level where the gross weight is within the load limit of the UTV or another vehicle Never exceed the load limit capacity of the UTV or another vehi...

Page 3: ...oint the spray gun at a human s body as high pressure spray may cause serious bodily harm After completing spraying task in the field turn the pump off at the switch and discharge the residual pressur...

Page 4: ...t not attempt to correct or remedy such defect either by modification of adjustment or alteration to any part or parts of the machine This Warranty will stop by right if the product is used in a manne...

Page 5: ...Pumps Sprayers does not pay for cleaning the sprayer parts accessories or work area before or after the warranty repair Clean up time is affected primarily by the application or conditions in which th...

Page 6: ...ing but may be used in conjunctions with a boom for boom spraying Please read the safety instructions before installing or operating your sprayer Specifications Model Tank Length Width Height Dry Weig...

Page 7: ...ction to 12 volt DC supply 12 Volt Model Only The sprayer requires a 12 volt DC power source A 2 metre loom is provided to allow the sprayer to be connected to the 12 volt DC battery The red wire is p...

Page 8: ...onda Engine Pressure Adjustment Gauge MAX 215 PSI Spare tap for Boom or XP Kit Engine Oil Dip Stick Hose Reel Lock Pump Oil Level Oil shouldnot exceed max line PumpSightGlass Oilshouldnot beseeninsigh...

Page 9: ...Adjustment Gauge MAX 580 PSI Engine Oil Dip Stick Hose Reel Lock PumpSightGlass Check oil level on pumpwhen running Oil shouldnot exceed max line Drain Tap Pump Suction Spare tap for Boom or XP Kit Ho...

Page 10: ...around and underneath the engine for signs of oil or gasoline leaks 2 Remove any excessive dirt or debris especially around the muffler and recoil starter 3 Look for signs of damage 4 Check that all s...

Page 11: ...gine switch to the ON position 5 Operate the starter Recoil starter by pulling the starter grip lightly until you feel resistance then pull briskly Return the starter grip gently DO NOT allow the star...

Page 12: ...this can result in some leakages or diaphragm failures 2 Be sure that the inlet and discharge hoses are not crimped and the strainer is clean In any case be sure connections are tight to prevent any...

Page 13: ...y are changed Always perform this routine maintenance on the pump at the end of the season Drain the oil from the pump by removing the pump heads one by one and the relevant piston sleeves Instruction...

Page 14: ...cking air or air hasn t been evacuated completely Valves blocked Check pressure in pulsatio damper The liquid flow is irregular The air in the pulsation damper is incorrectly set Top up with oil to co...

Page 15: ...Pumps Sprayers will not accept any liability for loss or damage consequential or otherwise arising directly or indirectly from the use of this equipment Chemical Advice BA Pumps Sprayers or their agen...

Page 16: ...h chemical container label conditions and nozzle type With nozzles that reduce spray drift to a minimum With booms as close to the ground as practicable With less than a 5km wind Using the correct per...

Page 17: ...0800 833 538 www bapumpsandsprayers com TSX400 PARTS LIST...

Page 18: ...0800 833 538 www bapumpsandsprayers com TSX400 PARTS EXPLODED...