Wireless Manual v.2.3 

Case 4 
Indicator with a closed contact switch to a SBL-4SG-XT400 

 TX 422A 

 RX 422A 

  TX 422B 

 RX 422B 

Ground 
     IO 1

 

Indicator 

XT400T 

SBL-4SG 

(422 LED Blink)

(RX LED Blink) 

(Configured for Input) 

(Configured for Output) 
(IO 1 jumper to 13 Green) 

Case 5 
Indicator with a remote zero/print switch near the Display 

 TX 422A    RX 422A 

232 TXD  232 RXD 

  TX 422B    RX 422B 

     GROUND       GND 

  Ground       Ground 
  Input 

     IO 1 

IO 1 

Indicator 

       XT400T 

      XT400T 

Remote 

  (422 LED Blink)

(RX LED Blink) 

  (232 LED Blink) 

 (Configured for Output) 

  (Configured for Input) 

 

Case 6 
A switch remotely controlling an AC Relay for a traffic light 

Ground 

NO 

      Ground 

Com 110VAC 

        IO 1 

IO 1 

NC

 

Indicator 

       XT400T 

      XT400T 

AC Relay 

  (Configured for input) 

 (Configured for Output) 

*You can reverse the logic by connecting the coils of the AC relay to IO 0 and +5 VDC instead of ground

Switch 

Switch 

Switch 

Summary of Contents for XT Series

Page 1: ...Wireless Manual v 2 4 Matko Wireless Installation Manual XT Series XT100 XT200 XT300 XT400 ...

Page 2: ...with Passive 20 mA Output 20 mA 20 mA 1 2 5 6 9 VDC GND JUMP CL JUMP CL Indicators with RS232 Output GND TXD 2 3 GND 232 RXD Indicators with RS422 Output TX 422A TX 422B 7 8 RX 422A RX 422B Figure 1 Wiring Diagram Compatibility All Matko XT Series transceivers and receivers are compatible with each other An XT300 Transceiver can talk to an XT100 Receiver however the units must have been configured...

Page 3: ...ll blink regardless of whether the receiver side has been properly configured or even powered on The red RX LED will blink on the receiver side with each data burst received from the matching transceiver Ideally with each green blink on the transceiver side there will be a corresponding red blink on the receiver side If the receiver side is infrequent the signal is not reliably getting from one un...

Page 4: ...22 LED Blink Case 2 Networked Indicators TX 422A RX 422A TX 422A RX 422A TX 422B RX 422B TX 422B RX 422B RX 422A TX 422A RX 422A TX 422A RX 422B TX 422B RX 422B TX 422B Indicator 1 XT300T XT300T Indicator 2 422 LED Blink 422 LED Blink RX LED Blink RX LED Blink Case 3 An Indicator to two remote displays with built in receivers Ground GND TX 232 RX 232 Indicator XT100T Remote 1 Remote 2 232 LED Blin...

Page 5: ...ay TX 422A RX 422A 232 TXD 232 RXD TX 422B RX 422B GROUND GND Ground Ground Input IO 1 IO 1 Indicator XT400T XT400T Remote 422 LED Blink RX LED Blink 232 LED Blink Configured for Output Configured for Input Case 6 A switch remotely controlling an AC Relay for a traffic light Ground NO Ground Com 110VAC IO 1 IO 1 NC Indicator XT400T XT400T AC Relay Configured for input Configured for Output You can...

Page 6: ...office and see if they communicate over a short distance If they do then reposition the units for better line of site or add a repeater to the system The RX LED blinks on the remote display side of my XT transceiver but the remote shows NoData The problem is probably with the wiring Make sure you are coming out a transmit on the XT unit and going into a receive on the remote display Try changing t...

Page 7: ... IDs 2 Digital output 841 500024 XT100 Series Transmitter Receiver in a NEMA 4 case Fixed at 9600 Baud rate and 1 System ID 841 500027 XT200 Series Transmitter Receiver in a NEMA 4 case Selectable Baud Rate and 2 System IDs Discontinued XT300 Series Transmitter Receiver in a NEMA 4 case Selectable Baud Rate and 16 System IDs Discontinued XT300 Series Transmitter Receiver in a NEMA 4 case Selectabl...

Reviews: